20
5
Electrical Connections
Note:
To disconnect or connect the electrical components
at the electrical connectors, the power supply must
be disconnected.
XENAX® Xvi 75V8S
5.1
Plug Arrangement
Description
Plug Type
RS232
USB-B socket
Real time Ethernet (optional)
2 x RJ45 socket with status LED
CANopen (optional)
9 Pol socket D-Sub
Ethernet TCP/IP
RJ45 socket with status LED
MOTOR
3 pole plug Wago, pitch 3,5mm
POWER / LOGIK
4 pole plug Wago, pitch 3,5mm
ENCODER HALL
15 pole plug D-Sub High Density
OPTIO
8 pole socket RJ45
PLC I/O
26 pole plug D-Sub High Density
START-UP / MASTER-SLAVE
2 x 4 pole plug USB-A
5.2
Plug Pin Configuration
5.2.1
USB/COM
USB-B Socket
The XENAX® is equipped with a standard USB-B
socket. I can be connected to a computer and it will
install a COM port for serial communication.
Optionally, it is possible to wire a plain RS232
connection from the XENAX® to the USB-B socket.
USB Socket
XENAX®
PC/SPS
1
N.C.
2
RX
TX
3
TX
RX
4
GND
GND
Pin 1
Pin 3
Pin 4
Pin 2