Jenn-Air W10201609B Installation Instructions And Use And Care Manual Download Page 19

19

ASSISTANCE OR SERVICE

When calling for assistance or service, please know the purchase 
date and the complete model and serial number of your 
appliance. This information will help us to better respond to your 
request.

If you need replacement parts

If you need to order replacement parts, we recommend that you 
use only factory specified parts. Factory specified parts will fit 
right and work right because they are made with the same 
precision used to build every new appliance. To locate factory 
specified replacement parts in your area, call us or your nearest 
designated service center.

In the U.S.A. 

If the problem is not due to one of the items listed in the 
“Troubleshooting” section…

Call the dealer from whom your appliance was purchased, or call 
Jenn-Air at 1-800-688-1100 to locate an authorized service 
company. When calling, please know the purchase date and the 
complete model and serial number of your appliance. Be sure to 
retain proof of purchase to verify warranty status. 

If the dealer or service company cannot resolve your problem, 
write to:

Jenn-Air Brand Home Appliances

Customer eXperience Center

553 Benson Road

Benton Harbor, MI 49022-2692

Web address: www.jennair.com

Or call: 1-800-688-1100

U.S. customers using TTY for deaf, hearing impaired or speech 
impaired, call: 1-800-688-2080

NOTE: When writing or calling about a service problem, please 
include the following information:

1. Your name, address and daytime telephone number.

2. Appliance model number and serial number.

3. Name and address of your dealer or servicer.

4. A clear description of the problem you are having.

5. Proof of purchase (sales receipt).

User’s guides, service manuals and parts information are 
available from Jenn-Air Brand Home Appliances, Customer 
eXperience Center.

In Canada

If the problem is not due to one of the items listed in the 
“Troubleshooting” section…

Call the dealer from whom your appliance was purchased, or call 
Jenn-Air at 1-800-807-6777 to locate an authorized service 
company. When calling, please know the purchase date and the 
complete model and serial number of your appliance. Be sure to 
retain proof of purchase to verify warranty status. 

If the dealer or service company cannot resolve your problem, 
write to:

Jenn-Air Brand Home Appliances

Customer eXperience Centre

1901 Minnesota Court

Mississauga, ON L5N 3A7

Web address: www.jennair.ca

Or call: 1-800-807-6777.

NOTE: When writing or calling about a service problem, please 
include the following information:

1. Your name, address and daytime telephone number.

2. Appliance model number and serial number.

3. Name and address of your dealer or servicer.

4. A clear description of the problem you are having.

5. Proof of purchase (sales receipt).

User’s guides, service manuals and parts information are 
available from Jenn-Air Brand Home Appliances, Customer 
eXperience Centre.

Accessories

NOTE: Instructions are included with each kit.

For model series JXDR7301V

30" (76.2 cm) one-piece trim:

Part Number W10187288 (black)

For model series JXDR7361V

36" (91.4 cm) one-piece trim:

Part Number W10187290 (black)

Summary of Contents for W10201609B

Page 1: ...1 800 JennAir 1 800 536 6247 or visit our website at www jennair com In Canada call 1 800 807 6777 or visit our website at www jennair ca Instructionsd installationetGuided utilisationetd entretien Au...

Page 2: ...SERVICE 19 WARRANTY 20 TABLE DES MATI RES S CURIT DU SYST ME DE VENTILATION 22 EXIGENCES D INSTALLATION 24 Outillage et pi ces 24 Exigences d emplacement 24 Sp cifications lectriques 26 Exigences conc...

Page 3: ...e instructions are not followed Your safety and the safety of others are very important We have provided many important safety messages in this manual and on your appliance Always read and obey all sa...

Page 4: ...osive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or into crawl spac...

Page 5: ...sult the cooktop manufacturer installation instructions before making any cutouts Check that the downdraft vent and cooktop location will clear the cabinet walls backsplash and rear wall studs inside...

Page 6: ...nt system will depend on your specific installation Top trim widths 30 76 8 cm for 30 76 2 cm vent 36 92 1 cm for 36 91 4 cm vent 13 34 3 cm retractable vent height 27 68 6 cm for 30 76 2 cm vent 33 8...

Page 7: ...e the wiring box cover Wire sizes must conform to the requirements of the National Electrical Code ANSI NFPA 70 latest edition or CSA Standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0...

Page 8: ...at you use round vent instead of rectangular vent especially if elbows are required If rectangular vent is required it should be transitioned to 6 15 2 cm round vent as soon as possible Maximum Length...

Page 9: ...screws to secure the brackets Vent Piece 6 15 2 cm Round 45 elbow 2 5 ft 0 8 m 90 elbow 5 0 ft 1 5 m 6 15 2 cm wall cap 0 0 ft 0 0 m 3 x 10 8 3 cm x 25 4 cm to 6 15 2 cm transition 4 5 ft 1 4 m 6 15 2...

Page 10: ...pencil marks on the face of the downdraft vent Tighten screws in legs Determine which direction is best for your installation When installed in a cabinet vent system can exhaust through the bottom ri...

Page 11: ...t away from the top mounting lip of the blower box and allow it to tilt away from the vent box panel 2 Lift up the blower box from the bottom mounting channel and set aside 3 Disconnect the wire conne...

Page 12: ...rew into place using the 4 screws 9 Replace the vent box over the blower motor 10 Place the bottom tab of the blower box into the bottom mounting channel 11 Tilt blower box top tab so it is flush with...

Page 13: ...p the blower box from the bottom mounting channel 3 Disconnect the wire connector from the blower motor 4 Remove panel from the opposite side of blower motor Loosen the 2 hex slotted head screws that...

Page 14: ...the top mounting bracket Slide bracket into the Z slots and tighten the 2 hex slotted head screws to secure 9 Reinstall panel to front side of vent box panel Place bottom tab of the panel into the bot...

Page 15: ...starter holes through undercounter mounting brackets into the underside of the countertop Insert appropriate length screws into holes and tighten brackets to countertop MakeElectricalConnections 1 Di...

Page 16: ...blower does not operate Check that filter or filters are pressed in as far as they will go Check that the circuit breaker has not tripped or a household fuse blown Check downdraft vent fuse located un...

Page 17: ...uit breaker box or fuse box 3 Allow plenty of time for the downdraft vent to dry naturally Do not open the downdraft vent to remove the water VENT SYSTEM CARE SurfaceofDowndraftVent To avoid damaging...

Page 18: ...BK W BR BU BK W BR BU F L1 C7 TR1 CN6 CN7 C4 N M M L L CN5 RL2 20 F 240 V NO DOWN OR W ELDD LIMIT SWITCHES NO UP GY W OR GY W FLAT CABLE CN8 CN2 CONN RL1 R GY GY BK R W BK BK C5 VDR1 FLAT CABLE PUSH...

Page 19: ...daytime telephone number 2 Appliance model number and serial number 3 Name and address of your dealer or servicer 4 A clear description of the problem you are having 5 Proof of purchase sales receipt...

Page 20: ...e service by an authorized Jenn Air servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance...

Page 21: ...21 Notes...

Page 22: ...cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Page 23: ...incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafond u...

Page 24: ...d installation fournies par le fabricant de la table de cuisson V rifier qu l emplacement d installation le syst me d extraction et la table de cuisson ne produiront pas d interf rence avec les paroi...

Page 25: ...couper d pend de la configuration d installation sp cifique Garniture sup rieure 30 76 8 cm pour syst me d extraction de 30 76 2 cm 36 92 1 cm pour syst me d extraction de 36 91 4 cm Mod le avec vent...

Page 26: ...National Electrical Code ANSI NFPA 70 ou de la norme CSA C22 1 94 Code canadien de l lectricit partie 1 et C22 2 No 0 M91 et de tous les codes et r glements en vigueur Deux connecteurs de conduit 12 7...

Page 27: ...ction On recommande d utiliser un conduit rond plut t qu un conduit rectangulaire en particulier si des coudes sont n cessaires Si un conduit rectangulaire est n cessaire il doit tre raccord un condui...

Page 28: ...oite sur l appareil Placer l embout sur le support du plan de travail faire glisser la patte dans la fente et l embo ter sur les pattes en plastique Composant Syst me de diam tre 6 15 2 cm Coude 45 2...

Page 29: ...che ou par le c t droit du placard vacuation par le fond Lors de l exp dition le syst me d extraction avec aspiration par le bas est configur pour l vacuation par le bas par cons quent aucune modifica...

Page 30: ...du c blage du moteur du ventilateur 4 ter les 2 vis de fixation de la bride de montage du moteur sur la bo te du syst me d extraction S parer le moteur du ventilateur et la bride de montage de la bo t...

Page 31: ...entilateur pour la placer en affleurement avec le panneau de la bo te du syst me d extraction et la positionner sous la bride de montage sup rieure 12 Faire glisser la bride dans les rainures en Z 13...

Page 32: ...profil de montage inf rieur en la soulevant 3 D connecter le connecteur du c blage du moteur du ventilateur 4 Retirer le panneau du c t oppos du moteur du ventilateur Desserrer les 2 vis t te hex fent...

Page 33: ...montage sup rieure Faire glisser la bride dans les rainures en Z et serrer les 2 vis t te hex fente droite 9 R installer le panneau sur le c t avant du panneau de la bo te du syst me d extraction Pla...

Page 34: ...s travers les brides de montage sous le plan de travail dans la face inf rieure du plan de travail Placer des vis de longueur appropri e pour bien fixer les brides sur le plan de travail Raccordements...

Page 35: ...loin qu il peut aller D terminer si le disjoncteur s est ouvert ou si un fusible est grill V rifier le fusible du syst me d extraction par le bas situ sous la carte de circuits d alimentation 5 Conne...

Page 36: ...Ne pas utiliser le syst me d extraction par le bas pendant une p riode suffisante pour que le s chage naturel soit complet Ne pas ouvrir le syst me d extraction par le bas pour liminer l eau ou autre...

Page 37: ...C7 TR1 CN6 CN7 C4 N M M L L CN5 RL2 20 F 240 V NO DOWN OR BL ELDD CONTACTEURS D TECTION DE LIMITE NO UP GRIS BL OR GRIS BL C BLE PLAT CN8 connecteur CN2 CONN RL1 R GRIS GRIS N R BL N N C5 VDR1 C BLE...

Page 38: ...hone durant la journ e 2 Num ros de mod le et de s rie de l appareil 3 Nom et adresse de votre marchand ou du service d entretien 4 Une description claire du probl me existant 5 Preuve d achat re u de...

Page 39: ...en Jenn Air autoris n est pas disponible 10 La d pose et la r installation de votre gros appareil si celui ci est install dans un endroit inaccessible ou n est pas install conform ment aux instruction...

Page 40: ...ous droits r serv s Registered Trademark Trademark of Jenn Air U S A Used under license by Maytag Limited in Canada Marque d pos e Marque de commerce de Jenn Air U S A Emploi sous licence au Canada 9...

Reviews: