11
4. Place the bottom tab of the blower box into the bottom
mounting channel.
5. Tilt blower box top tab so it is flush with the vent box panel
and position it under the top mounting bracket. Slide bracket
into the “Z” slots and tighten the 2 hex/slotted head screws
to secure.
6. See “Complete Installation” section.
Rear Venting:
1. Remove the vent box. Loosen the 2 hex/slotted head screws
that attach the top bracket that secures the motor to the vent
box enough to slide the bracket into the “Z” slots. This will
move the bracket away from the top mounting lip of the
blower box and allow it to tilt away from the vent box panel.
2. Lift up the blower box from the bottom mounting channel and
set aside.
3. Disconnect the wire connector from the blower motor.
4. Remove the 2 screws that mount the motor mounting bracket
to the vent box. Remove the blower motor and mounting
bracket assembly from the vent box.
5. Remove the 4 screws from the small cover plate on the rear
of the vent chamber and set screws and cover plate aside.
A. Blower box
B. Bottom mounting channel
A. Bracket with “Z” slots
B. Hex/slotted head screws (2)
A
B
B
A
B
A. Blower box
B. Bottom mounting channel
A. Blower motor
B. Wire connector
A. Blower motor mounting bracket screws (2)
A
B
A
B
A
A
Summary of Contents for W10201609B