20
16023510
©2004 Maytag Services
Disassembly Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death, disconnect power to cooktop before servicing, unless
testing requires power.
Grease Filter Removal
The grease filter rests against the vent opening and plenum ventilation chamber.
1. Remove air grill.
2. Remove grease filter by grasping the “D“ ring (located along the top edge of the filter) and pulling slightly outward
and upward until the filter clears the air chamber.
3. Reverse procedure to replace grease filter.
Blower Removal
1. Shut off gas supply and disconnect electricity to unit.
2. Gain access to blower motor assembly, located under the cooktop surface.
3. Remove screws securing blower motor assembly to cooktop frame or other cabinet surface.
4. Remove screws securing blower motor assembly to ductwork.
5. Disassemble blower motor assembly to replace appropriate part.
6. Reverse procedures to reassembly/reinstall blower motor assembly.
Grease
Filter
Blower
Blower
Wheel
Motor
Cover
Motor
Band
Access
Cover
Fan
Relay
Plenum
Assembly
Retainer
JGD8348CDP BLOWER MOTOR ASSEMBLY breakdown
Summary of Contents for PRO-STYLE JGD8348CDP
Page 21: ...2004 Maytag Services 16023565 A 1 Appendix A...
Page 25: ...2004 Maytag Services 16023565 A 5 Installation Instructions Ducting Instructions JGD8348CDP...
Page 26: ...A 6 16023565 2004 Maytag Services Installation Instructions Ducting Instructions JGD8348CDP...
Page 27: ...2004 Maytag Services 16023565 A 7 Installation Instructions Ducting Instructions JGD8348CDP...
Page 28: ...A 8 16023565 2004 Maytag Services Installation Instructions Ducting Instructions JGD8348CDP...
Page 31: ...2004 Maytag Services 16023565 B 1 Appendix B...