Jenn-Air JXU9130WP0 Installation Instructions Manual Download Page 7

7

INSTALLATION INSTRUCTIONS

Prepare Location

It is recommended that the vent system be installed before 
hood is installed.

If you are installing an optional backsplash or full width duct 
cover, follow the instructions included with that product.

Before making cutouts, make sure there is proper clearance 
within the ceiling or wall for exhaust vent.

Check your ceiling height and the hood height maximum 
before you select your hood.

1.

Disconnect power.

2.

Determine which venting method to use: roof, wall, or 
non-vented.

3.

Select a flat surface for assembling the range hood. 
Place covering over that surface.

4.

Using 2 or more people, lift range hood onto covered surface.

NOTE:

 This range hood can be mounted to the cabinets or to the 

wall.

For Cabinet Installations

1.

If cabinet has recessed bottom, add wood filler strips on each 
side. Install screws to attach filler strips in locations shown.

Determine Wiring Hole Location

Cut only one 1

¹⁄₄

" (3.2 cm) diameter wiring access hole. 

See Step 2 for wiring hole location instructions.

1.

Determine and clearly mark a vertical centerline on the wall 
and cabinet in the area the vent opening will be made.

2. To wire through top:

 

Mark a line distance “A” from the left of the centerline on the 
underside of the cabinet. Mark the point on this line that is 
7

⁷⁄₈

" (20.0 cm) from back wall. Drill a 1¼" (3.2 cm) diameter 

hole through the cabinet at this point.

Cut Openings for 3¼" x 10" (8.3 cm x 25.4 cm) 
Rectangular Vent System
Roof Venting

To make a 3½" x 10½" (8.9 cm x 26.7 cm) rectangular cutout 
on the underside of cabinet top and bottom:

1.

Mark lines 

³⁄₈

" (1.0 cm) and 3

⁷⁄₈

" (9.8 cm) from the back wall 

on the centerline of the underside of cabinet.

2.

Mark lines 5¼" (13.3 cm) to the right and left of the centerline 
on the underside of cabinet.

3.

Use saber or keyhole saw to cut a rectangular opening for 
vent.

WARNING

Excessive Weight Hazard

Use two or more people to move and install 
range hood.

Failure to do so can result in back or other injury.

Cabinet
bottom

Wall

3" (7.6 cm)

Wood filler strips

(recessed cabinet

bottoms only)

3" (7.6 cm)

A. Centerline

A. 12

³⁄₁₆

" (31.0 cm) 

A

Centerline

7

⁷⁄₈

" (20.0 cm)

from wall,
not cabinet
frame

A

Summary of Contents for JXU9130WP0

Page 1: ...536 6247 or visit our website at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien A...

Page 2: ...TTE 25 Nettoyage 25 SCH MA DE C BLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 28 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be k...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 4: ...installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the ve...

Page 5: ...as close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater th...

Page 6: ...aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and...

Page 7: ...g access hole See Step 2 for wiring hole location instructions 1 Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made 2 To wire through to...

Page 8: ...2 cm and a suggested maximum of 36 91 4 cm above the range to the bottom of the hood Mark a reference line on the wall 3 Using 2 or more people center the hood on the vertical centerline then align th...

Page 9: ...e damper and the wall cap do not interfere with each other Remove the damper from the 3 x 10 8 3 x 25 4 cm rectangular vent connector if they interfere 5 Using 2 or more people lift the hood into fina...

Page 10: ...minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the right hand underside of the range hood Range Hood Controls Operating the light...

Page 11: ...l grease filters as needed in a dishwasher or hand wash in a hot detergent solution to clean To Reinstall Metal Grease Filters 1 Grasp filter handles and place rear of filter into rear track 2 Push do...

Page 12: ...12 WIRING DIAGRAM VARISTOR BK BK BK BK BK WH WH WH WH BU BK GY RD WH BU BK WH WH BU BU GY GY BK BK RD RD YL YL BR BR YL GN YL GN WH BK WH BK YL GN BK BK WH WH YL GN YL GN WH BK BU...