INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.

Tools needed

Level

Drill with 1¼" (3.0 cm), 

³⁄₁₆

" (4.8 mm), 

¹⁄₈

" (3.0 mm), and 

⁵⁄₁₆

(7.9 mm) drill bits

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Metric hex key set

Parts needed

Home power supply cable

½" (12.7 mm) UL listed or CSA approved strain relief

3 UL listed wire connectors

1 wall or roof cap

Metal vent system

Parts supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and light bulbs 
installed

3¼" x 10" (8.3 x 25.4 cm) rectangular vent connector

2 metal grease filters for 30" (76.2 cm) model

3 metal grease filters for 36" (91.4 cm) model

T20

®

 Torx

®† 

adapter

4 - 5 x 45 mm mounting screws

6 - 4.5 x 13 mm screws

3 - 4 x 8 mm screws

4 - 10 x 50 wall anchors

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial/rating plate. The model/serial/rating 
plate is located behind the left filter on the rear wall of the vent 
hood.
Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. 
Given dimensions provide minimum clearance.

Grounded electrical outlet is required. See “Electrical 
Requirements” section.

The canopy hood is factory set for venting through the roof or 
wall. 
All openings in ceiling and wall where canopy hood will be 
installed must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.

Product Dimensions

Front View

†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.

12"

(30.5 cm)

2" 

(5.1 cm)

30" (76.2 cm)
36" (91.4 cm)

23" (58.4 cm)

10" 

(25.4 cm)

³⁄₈

"

(1.0 cm)

2

⁹⁄₁₆

(6.5 cm)

7½"

(19.0 cm)

29

¹⁄₈

" (74.0 cm): 30" (76.2 cm) models 

35

¹⁄₈

" (89.2 cm): 36" (91.4 cm) models 

Summary of Contents for JXU9130WP0

Page 1: ...536 6247 or visit our website at www jennair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien A...

Page 2: ...TTE 25 Nettoyage 25 SCH MA DE C BLAGE 26 ASSISTANCE OU SERVICE 27 Au Canada 27 Accessoires 27 GARANTIE 28 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be k...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 4: ...installer s responsibility to comply with installation clearances specified on the model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the ve...

Page 5: ...as close as possible to where the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater th...

Page 6: ...aluminum wiring follow the procedure below 1 Connect a section of solid copper wire to the pigtail leads 2 Connect the aluminum wiring to the added section of copper wire using special connectors and...

Page 7: ...g access hole See Step 2 for wiring hole location instructions 1 Determine and clearly mark a vertical centerline on the wall and cabinet in the area the vent opening will be made 2 To wire through to...

Page 8: ...2 cm and a suggested maximum of 36 91 4 cm above the range to the bottom of the hood Mark a reference line on the wall 3 Using 2 or more people center the hood on the vertical centerline then align th...

Page 9: ...e damper and the wall cap do not interfere with each other Remove the damper from the 3 x 10 8 3 x 25 4 cm rectangular vent connector if they interfere 5 Using 2 or more people lift the hood into fina...

Page 10: ...minutes after the cooking is complete to clear all smoke and odors from the kitchen The hood controls are located on the right hand underside of the range hood Range Hood Controls Operating the light...

Page 11: ...l grease filters as needed in a dishwasher or hand wash in a hot detergent solution to clean To Reinstall Metal Grease Filters 1 Grasp filter handles and place rear of filter into rear track 2 Push do...

Page 12: ...12 WIRING DIAGRAM VARISTOR BK BK BK BK BK WH WH WH WH BU BK GY RD WH BU BK WH WH BU BU GY GY BK BK RD RD YL YL BR BR YL GN YL GN WH BK WH BK YL GN BK BK WH WH YL GN YL GN WH BK BU...

Page 13: ...iances with any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your corresponde...

Page 14: ...rs preservation solutions etc 5 Defects or damage caused by the use of non genuine Jenn Air parts or accessories 6 Conversion of products from natural gas or L P gas 7 Damage from accident misuse abus...

Reviews: