INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed here.

Tools Needed

Level

Drill with 1¼" (3.0 cm), 

³⁄₈

" (9.5 mm), 

⁷⁄₆₄

" (2.75 mm) and 

¹⁄₈

" (3.0 mm) drill bits

Pilot hole drill bits (determined by chimney support 
attachment method)

Pencil

Wire stripper or utility knife

Tape measure or ruler

Pliers

Caulking gun and weatherproof caulking compound

Vent clamps

Jigsaw or keyhole saw

Flat-blade screwdriver

Metal snips

Phillips screwdriver

Parts Needed

Home power supply cable

2 - ½" (12.7 mm) UL listed or CSA approved strain reliefs

3 UL listed wire connectors

For vented installations, you will also need: 

1 - Wall or roof cap

Metal vent system

For non-vented (recirculating) installations, you will also need:

Recirculating Kit Part Number W10692909 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.

6" (15.2 cm) round metal vent duct. Length required is 
determined by ceiling height. 

Parts Supplied

Remove parts from packages. Check that all parts are included.

Hood canopy assembly with ventilator and LED light installed

Filter—installed in hood canopy

60 - 4.2 x 8 mm screws

4 - 5 x 45 mm screws

Mounting template

2 - Upper vent covers

2 - Lower vent covers

Vent transition with backdraft damper installed

2 - 3.5 x 9.5 mm mounting screws

4 - Plastic vent clips

Upper horizontal support bracket

Horizontal support

8 - Vertical supports

4 - 3.5 x 6.5 mm screws

2 - 2.9 x 3 mm screws

T10 Torx

 adapter

T20

®

 Torx

®

 adapter

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances.

Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial/rating plate. The model/serial/rating 
plate is located behind the left filter on the rear wall of the vent 
hood.
Canopy hood location should be away from strong draft areas, 
such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
Because of the size and weight of this island hood, the chimney 
support must be securely attached to the ceiling.

For plaster or drywall ceilings, the chimney support must be 
attached to joists. If this is not possible, you must build a 
support structure behind the plaster or drywall. The support 
structure must be able to support 100 lbs (45.4 kg).

This range hood is recommended for use with cooktops with a 
maximum total rating of 78,000 BTUs or less.
The range hood is factory set for venting through the roof.
For non-vented (recirculating) installation, see “Non-vented 
(recirculating) Installations” in “Install Range Hood” section. 
Recirculation Kit Part Number W10692909 is available from your 
dealer or an authorized parts distributor. 
All openings in ceiling and wall where range hood will be installed 
must be sealed.

For Mobile Home Installations

The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local 
codes.

Product Dimensions

*Vented installations only

**Non-vented (recirculating) installations only

†®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.

12

¹⁄₄

"

 

(31.0 cm)

13

³⁄₁₆

"

(33.5 cm)

36" (91.2 cm)

*32

¹⁄₂

(82.6 cm)

min.

*46

¹⁄₂

"

 

(118.0 cm)

max.

**32

¹⁄₂

"

 

(82.6 cm)

min.

**52

⁹⁄₁₆

(133.5 cm)

max.

27" (68.6 cm)

Summary of Contents for JXI8536DS

Page 1: ...nnair com In Canada call 1 800 JENNAIR 1 800 536 6247 or visit our website at www jennair ca Instructions d installation et Guide d utilisation et d entretien Au Canada pour assistance installation ou...

Page 2: ...OTTE 28 Nettoyage 28 SCH MA DE C BLAGE 29 ASSISTANCE OU SERVICE 30 Au Canada 30 Accessoires 30 GARANTIE 31 RANGE HOOD SAFETY You can be killed or seriously injured if you don t immediately You can be...

Page 3: ...3 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS...

Page 4: ...model serial rating plate The model serial rating plate is located behind the left filter on the rear wall of the vent hood Canopy hood location should be away from strong draft areas such as windows...

Page 5: ...to seal exterior wall or roof opening around the cap The size of the vent should be uniform Cold Weather Installations An additional back draft damper should be installed to minimize backward cold air...

Page 6: ...ark Quincy MA 02169 7471 CSA International 8501 East Pleasant Valley Road Cleveland OH 44131 5575 A 120 volt 60 Hz AC only 15 amp fused electrical circuit is required If the house has aluminum wiring...

Page 7: ...power supply cable and drill a 1 3 cm diameter hole for wire access 2 Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local codes and ordin...

Page 8: ...Use caulk to seal all openings Non Vented Recirculating Installation 1 Attach the air deflector to the upper horizontal support using 4 mounting screws 2 Measure the length of 6 15 2 cm duct needed to...

Page 9: ...ame The larger hole in the flanges of the upper duct cover must be outside the smaller hole in the mating flange of the other upper duct cover 2 Secure the upper duct covers together with two 3 5 x 6...

Page 10: ...over the plastic clip to secure the lower duct covers together at the bottom 7 Secure the lower duct covers together at the top using 2 plastic clips Use one plastic clip on each side 8 Secure the lo...

Page 11: ...tween the gas cooktop and electric cooktop modes The Auto button light will flash 5 times when the range hood is changed to the electric cooktop mode Auto Sense is now set to work with electric cookto...

Page 12: ...Cleaning Method Liquid detergent soap and water or all purpose cleanser Wipe with damp soft cloth or nonabrasive sponge then rinse with clean water and wipe dry Metal Grease Filter 1 Open the stainle...

Page 13: ...or Specifications Power Supply Frequency Power Absorbtion 120 VAC 60 HZ 420 W Motor Resistance Blue Black Blue Grey Blue Red Blue White 9 8 14 3 18 21 6 SE130B RD M 3 2 1 4 5 6 7 8 9 BU YL GN BR YL WH...

Page 14: ...h any questions or concerns at Jenn Air Brand Home Appliances Customer eXperience Center 553 Benson Road Benton Harbor MI 49022 2692 Please include a daytime phone number in your correspondence In Can...

Page 15: ...light bulbs batteries air or water filters preservation solutions etc 5 Conversion of products from natural gas or L P gas 6 Damage from accident misuse abuse fire floods acts of God or use with prod...

Page 16: ...re appareil m nager Assurez vous de toujours lire tous les messages de s curit et de vous y conformer AVERTISSEMENT DANGER Voici le symbole d alerte de s curit Ce symbole d alerte de s curit vous sign...

Page 17: ...ue d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plafo...

Page 18: ...ponsabilit de respecter les distances de s paration exig es sp cifi es sur la plaque signal tique de l appareil La plaque signal tique de l appareil est situ e derri re le filtre de gauche sur la paro...

Page 19: ...uniquement Un conduit en m tal rigide est recommand Ne pas utiliser de conduit de plastique ou d aluminium Le syst me d vacuation doit comporter un clapet Si la bouche de d charge murale ou par le toi...

Page 20: ...e peut causer une r tropression et des turbulences de l air ce qui r duit consid rablement la performance La sortie l ext rieur du circuit d vacuation peut se faire travers le toit ou travers un mur P...

Page 21: ...e un d gagement suffisant dans le plafond pour le conduit d vacuation La hotte doit tre install e 24 61 cm min des surfaces de cuisson lectriques ou 27 68 6 cm min des surfaces de cuisson au gaz et un...

Page 22: ...er Assemblage et installation de la hotte 1 Installer le raccord de transition au sommet de la hotte s il a t enlev pour exp dition avec 2 vis de t lerie de 3 5 x 9 5 mm 2 Positionner les 4 supports v...

Page 23: ...o tier de connexion 3 ter l opercule arrachable du bo tier de connexion et installer un serre c ble de homologation UL ou CSA 4 Acheminer le cordon d alimentation du domicile travers le serre c ble da...

Page 24: ...de support Le trou le plus gros sur les rebords de la partie sup rieure du cache conduit doit se trouver l ext rieur du trou le plus petit sur le rebord en contact de l autre partie sup rieure du cach...

Page 25: ...ds de la partie sup rieure du cache conduit S assurer que les parties inf rieures avant et arri re des cache conduits communiquent correctement REMARQUE Lors de l assemblage de la partie inf rieure ar...

Page 26: ...que met la hotte en marche automatiquement lorsqu elle d tecte une chaleur sup rieure la limite de temp rature permise Lorsque la fonction Auto Sense d tection automatique est activ e la vitesse du ve...

Page 27: ...en continu Apr s 15 minutes le ventilateur s teint automatiquement 2 Lorsque la minuterie du ventilateur est en marche appuyer encore une fois sur le bouton correspondant la vitesse de ventilateur d...

Page 28: ...llique vers le haut et rel cher la poign e pour embo ter le loquet 7 R p ter les tapes 1 5 pour l autre filtre 8 Fermer le panneau en acier inoxydable Fixer en engageant les 2 pitons dans les loquets...

Page 29: ...eur de vitesse automatique Interface utilisateur JA BU BU BL BL N Del Del N R N Rampe de Del Rampe de Del R R N N BU BL BL N Del Del N R N R N N R N R R JA VE MAR JA Nue Ph Terre JA VE Filtre interf r...

Page 30: ...la garantie des produits et fournir un service apr s la garantie partout au Canada Caract ristiques et sp cifications de notre gamme compl te d appareils m nagers R f rences aux concessionnaires locau...

Page 31: ...utions de conservation etc 5 Conversion de votre produit du gaz naturel ou du gaz de p trole liqu fi 6 Dommages caus s par accident m susage abus incendie inondations catastrophe naturelle ou l utilis...

Page 32: ...W10674115C 2014 Jenn Air Used under license in Canada All rights reserved Utilis sous licence au Canada Tous droits r serv s 9 14 Printed in Mexico Imprim au Mexique...

Reviews: