 DETAILED PLANNING DIMENSIONS

4 of 4

IMPORTANT:

 Dimensional specifications are provided for planning purposes only.  

Do not make any cutouts based on this information.

 Refer to the Installation Guide 

before

 

selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.  
All Jenn-Air

®

 appliances are appropriately UL, CUL or CSA approved.

8457AdZw615

e

A

E

F

C

A

B

C

B

G

Side Cleat*

1

5

/

8

" (4.1 cm)

Side Cleat*

1" (2.5 cm) 

Side Cleats*

7

/

8

" (2.2 cm) 

Platform*

Back of Cabinet

G

D

Bottom of Cutout

Back of

Cabinet

A

C

B

I

H

G

F

B

A

D

E

F

G

H

D

E

C

Power Cord Location

e

A

E

F

C

A

B

C

B

G

Side Cleat*

1

5

/

8

" (4.1 cm)

Side Cleat*

1" (2.5 cm) 

Side Cleats*

7

/

8

" (2.2 cm) 

Platform*

Back of Cabinet

G

D

e

A

E

F

C

A

B

C

B

G

Side Cleat*

1

5

/

8

" (4.1 cm)

Side Cleat*

1" (2.5 cm) 

Side Cleats*

7

/

8

" (2.2 cm) 

Platform*

Back of Cabinet

G

D

OPENING/CLEARANCE DIMENSIONS

FRONT VIEW

SIDE VIEW

BACK VIEW

30"/27" WARMING DRAWERS – FLUSH INSTALLATION

JWD3030E – 29

3

4

" x 10

1

4

" x 24

1

2

(depth without handle)

JWD3027E – 26

3

4

" x 10

1

4

" x 24

1

2

(depth without handle)

MODEL #

JWD3030E

JWD3027E

in

cm

in

cm

A

Width of flush inset cutout (min.)

30

1

4

76.8

27

1

4

69.2

B

Width of opening (min.)

 28

1

4

71.8

 25

1

4

64.1

C

Height between cutouts (min.)

2

1

2

6.4

2

1

2

6.4

D

Height of opening (min.)

9

1

8

23.2

9

1

8

23.2

E

Height of flush inset cutout (min.)

10

3

4

27.3

10

3

4

27.3

F

Bottom of cutout to floor (recommended) 

8

1

4

21.0

8

1

4

21.0

Bottom of cutout to floor (min.)

5

12.7

5

12.7

G

Depth of cutout (min.)

25

3

8

64.5

25

3

8

64.5

e

Recommended outlet location

ELECTRICAL REQUIREMENTS

120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required. A dedicated circuit  
is recommended.
If the outlet is on the rear wall behind the warming drawer, it must be recessed and located in 
the upper right-hand corner. If outlet is located in an adjacent cabinet, drill a 1

3

8

" (3.5 cm) 

minimum diameter hole in the side wall or support surface to access the power supply cord.

LOCATION REQUIREMENTS

Support surface must be solid, level and flush with the bottom of the cabinet cutout.  
The warming drawer must be leveled before completing installation. 

FLUSH INSTALLATION REQUIREMENTS

A 25

3

8

" (64.5 cm) minimum cutout depth is required.

These dimensions will result in a 

1

4

" (0.6 cm) reveal on all sides of the warming drawer.

The front face of the cleats and platforms will be visible and should be treated as a finished surface.

TOP VIEW

* Cleats and platform must be recessed 1" (2.5 cm) from the front of the cabinet.