background image

6

Electrical Requirements

If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine 
that the ground path and the wire gauge are in accordance 
with local codes.

Check with a qualified electrical installer if you are not sure the 
oven is properly grounded.

This oven must be connected to a grounded metal, permanent 
wiring system.

Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition or CSA Standards C22.1-94, Canadian 
Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and 
all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471

CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575

Electrical Connection

To properly install your oven, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.

Oven must be connected to the proper electrical voltage and 
frequency as specified on the model/serial/rating plate. The 
model/serial/rating plate is located under the control panel on 
single ovens and under the control panel on the upper oven 
cavity on double ovens. See the following illustrations.

Models rated from 7.3 to 9.6 kW at 240 volts (5.4 to 7.4 kW 
at 208 volts) require a separate 40-amp circuit. Models 
rated at 4.8 kW and below at 240 volts (3.6 kW and below 
at 208 volts) require a separate 20-amp circuit.

A circuit breaker is recommended.

Connect directly to the circuit breaker box (or fused 
disconnect) through flexible, armored or nonmetallic 
sheathed, copper cable (with grounding wire). See “Make 
Electrical Connection” section. 

Flexible conduit from the oven should be connected directly 
to the junction box.

Fuse both sides of the line.

Do not cut the conduit. The length of conduit provided is for 
serviceability of the oven.

A UL listed or CSA approved conduit connector must be 
provided.

If the house has aluminum wiring, follow the procedure 
below:

1. Connect a section of solid copper wire to the ends of the 

flexible conduit leads.

2. Connect the aluminum wiring to the added section of 

copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.

For power requirements for models JJW2430D, JJW2427D, 
JJW2830D, JJW2827D, JJW2730D, JJW2727D, JJW3430D and 
JJW3820D, refer to the following table.

Single Oven

A. Model/serial/rating plate

Double Oven

A. Model/serial/rating plate

A

A

240 VAC

208 VAC

Model

Watts

Amps

Watts

Amps

JJW2430D

JJW2427D

4141

17.8

3145

15.6

JJW3430

4193

18.3

3193

16.1

JJW2830D

JJW2827D

8279

35.7

6288

31.2

JJW3820D

8363

36.6

6386

32.1

JJW2730D

JJW2727D

8221

34.3

6230

30.7

Summary of Contents for JJW2427DS

Page 1: ...ns Installed Above Warming Drawers 15 Complete Installation 16 S CURIT DU FOUR ENCASTR 17 EXIGENCES D INSTALLATION 17 Outillage et pi ces 17 Exigences d emplacement 18 Sp cifications lectriques 21 INS...

Page 2: ...0 76 2 cm kit Order Part Number W10752681A for black 30 76 2 cm kit Order Part Number W10752683A for stainless steel 30 76 2 cm kit To order see the Assistance or Service section of the Use and Care G...

Page 3: ...lbs 70 kg for 30 76 2 cm models Floor must be able to support a double oven weight of 251 lbs 114 kg for 27 68 6 cm models or 288 lbs 131 kg for 30 76 2 cm models IMPORTANT To avoid damage to your cab...

Page 4: ...tertop C 5 13 3 cm bottom of cutout to floor D 28 72 4 cm cutout width E 28 71 2 cm min cutout height A B C D E 27 68 6 cm models A 27 68 6 cm min cabinet width B 2 5 5 cm top of cutout to bottom of u...

Page 5: ...from back of control panel to start of strain relief G 66 167 6 cm flexible conduit length C B A E D G F 27 68 6 cm models A 27 68 6 cm min cabinet width B 2 5 5 cm top of cutout to bottom of upper ca...

Page 6: ...at 240 volts 5 4 to 7 4 kW at 208 volts require a separate 40 amp circuit Models rated at 4 8 kW and below at 240 volts 3 6 kW and below at 208 volts require a separate 20 amp circuit A circuit break...

Page 7: ...ocate the oven door hinge locks in both corners of the oven door and then rotate the hinge locks toward the oven door to the unlocked position If the door hinge lock is not rotated fully see illustrat...

Page 8: ...r locked position 6 Close the oven door 7 When the hinges are properly installed and the door closed there should be an even gap between the door and the control panel If one side of the oven door is...

Page 9: ...rical Connection section Cutout Height is Between 28 and 29 72 8 cm and 74 8 cm 1 Using 2 or more people place the oven on its back on a covered surface 2 Remove the foot from the right front spacer b...

Page 10: ...talled in a cutout height between 48 and 52 124 1 cm and 132 6 cm Refer to the following instructions to position the feet for the size of your cabinet cutout Cutout Height is Between 48 50 124 1 cm a...

Page 11: ...n the same manner install a foot on the right rear of the oven 4 Install a front foot on the left front spacer using a 8 18 x screw NOTE Position the foot so the long side of the foot is facing toward...

Page 12: ...en 3 In the same manner install a foot on the right rear of the oven 4 Install a front foot on the left front using a 8 18 x screw NOTE Position the foot so the long side of the foot is facing toward...

Page 13: ...wires C together using a UL listed wire connector 3 Untwist white wire from green or bare ground wire coming from the oven 4 Connect the 2 white wires F together using a UL listed wire connector 5 Co...

Page 14: ...en into the cabinet Do not push against the outside edges 2 Push against the seal area of the front frame to push the oven into the cabinet until the back surface of the front frame touches the front...

Page 15: ...ing two 8 18 x screws on each side NOTE On 27 68 6 cm models only one 8 18 x screw is used on each side Align vent tab B with oven frame A as shown Using one 8 18 x screw E on each side of the vent ta...

Page 16: ...3 Dispose of recycle all packaging materials 4 For oven use and cleaning read the Use and Care Guide Check Operation of Single and Double Ovens 1 Turn on power 2 At first use set up the clock and any...

Page 17: ...de 30 76 2 cm Commander la pi ce W10752681A pour l ensemble noir de 30 76 2 cm Commander la pi ce W10752683A pour l ensemble en acier inoxydable de 30 76 2 cm Pour commander voir la section Assistanc...

Page 18: ...our les mod les de 30 76 2 cm Le plancher doit pouvoir supporter le poids d un four double de 251 lb 114 kg pour les mod les de 27 68 6 cm ou 288 lb 131 kg pour les mod les de 30 76 2 cm IMPORTANT Afi...

Page 19: ...ur de l ouverture d coup e 28 72 4 cm E Hauteur de l ouverture d coup e 28 71 2 cm min A B C D E Mod les de 27 68 6 cm A Largeur du placard 27 68 6 cm min B 2 5 5 cm entre le sommet de l ouverture d c...

Page 20: ...F Mod les de 27 68 6 cm A Largeur du placard 27 68 6 cm min B 2 5 5 cm entre le sommet de l ouverture d coup e et la porte du placard sup rieur C 14 37 5 cm entre le bas de l ouverture d coup e et le...

Page 21: ...endant de 40 A Un mod le de 4 8 kW ou moins 240 volts 3 6 kW ou moins 208 volts doit tre aliment par un circuit ind pendant de 20 A On recommande d utiliser un disjoncteur Raccorder l appareil directe...

Page 22: ...t aussi utiliser les corni res de l emballage 2 Ouvrir la porte du four 3 Identifier les loquets de charni re de la porte du four dans les deux angles de la porte faire pivoter les loquets de charni r...

Page 23: ...soit compl tement ouverte Si la porte du four ne s ouvre pas compl tement un angle de 90 r p ter les tapes 1 3 5 Identifier les loquets de charni re de la porte du four dans les angles de la porte fa...

Page 24: ...ent lectrique La hauteur de la cavit d encastrement est comprise entre 26 et 27 68 4 cm et 70 3 cm 1 l aide d au moins 2 personnes placer le four sur sa partie arri re sur une surface couverte 2 Retir...

Page 25: ...ur en position verticale 7 Passer la section Raccordement lectrique Fours doubles En modifiant le positionnement des pieds du four on peut installer un four double dans une cavit d encastrement d une...

Page 26: ...t du four 3 De la m me mani re installer un pied sur la partie arri re droite du four 4 Installer un pied avant sur la cale d espacement avant gauche avec une vis n 8 18 x REMARQUE Positionner le pied...

Page 27: ...du four 3 De la m me mani re installer un pied sur la partie arri re droite du four 4 Installer un pied avant sur la partie avant gauche avec une vis n 8 18 x REMARQUE Positionner le pied de fa on ce...

Page 28: ...erminer l installation correspondant votre type de raccordement lectrique Tableau des options de raccordement lectrique Fours doubles Fours simples AVERTISSEMENT Risque de choc lectrique D connecter l...

Page 29: ...codes locaux autorisent un tel raccordement 1 Connecter ensemble les 2 conducteurs noirs C avec un connecteur de fils homologation UL 2 Connecter les 2 conducteurs blancs D et le conducteur vert ou n...

Page 30: ...vis 5 L vent inf rieur et la garniture de l vent inf rieur n cessaires lorsque le four est install avec les pieds en position haute sont livr s dans l emballage en mousse situ sur le dessus du four P...

Page 31: ...vement et PF devrait appara tre sur l affichage 13 Si le tableau d affichage ne s allume pas consulter la section Garantie du guide d utilisation et d entretien Installationdel ensembleded flecteurdu...

Page 32: ...ou LOWER BROIL cuisson au gril four inf rieur 4 R gler la temp rature 5 Appuyer sur START mise en marche Si le s four s ne fonctionne nt pas contr ler ce qui suit Les fusibles du domicile sont intact...