THIS PRODUCT SHOULD NOT BE INSTALLED BELOW VENTILATION TYPE HOOD SYSTEM THAT DIRECTS AIR IN A DOWNWARD DIRECTION.

THESE SYSTEMS MAY CAUSE IGNITION AND COMBUSTION PROBLEMS WITH THE GAS BURNERS RESULTING IN PERSONAL INJURY AND MAY
EFFECT THE COOKING PERFORMANCE OF THE UNIT.

NOTE:

THE FIGURE MAY NOT ACCURATELY REPRESENT YOUR RANGE COOKTOP; HOWEVER, THIS WARNING APPLIES TO ALL GAS COOKING

PRODUCTS.

CE PRODUIT NE DOIT PAS ÊTRE INSTALLÉ SOUS UNE HOTTE D’EXTRACTION QUI RENVOIE L’AIR VERS LE BAS.

CES SYSTÈMES PEUVENT ENTRAÎNER DES PROBLÈMES D’INFLAMMATION ET DE COMBUSTION AVEC LES BRÛLEURS
À GAZ, ENTRAÎNANT DES BLESSURES ET RISQUANT D’AFFECTER LA PERFORMANCE DE CUISSON DE L’APPAREIL.

REMARQUE :

L’ILLUSTRATION PEUT NE PAS REPRÉSENTER PRÉCISÉMENT LA TABLE DE CUISSON DE VOTRE

CUISINIÈRE; CEPENDANT, CET AVERTISSEMENT CONCERNE TOUS LES APPAREILS DE CUISSON À GAZ.

ESTE PRODUCTO NO SE DEBE INSTALAR DEBAJO DE SISTEMAS DE CAMPANAS DE VENTILACIÓN QUE DIRIJAN EL
FLUJO DE AIRE HACIA ABAJO.

ESTOS SISTEMAS PUEDEN CAUSAR PROBLEMAS DE ENCENDIDO Y DE COMBUSTIÓN DE LOS QUEMADORES, LO
QUE PUEDE RESULTAR EN LESIONES PERSONALES Y AFECTAR EL RENDIMIENTO DE LA COCCIÓN DE LA UNIDAD.

NOTA:

LA FIGURA PUEDE NO REPRESENTAR CON EXACTITUD SU CUBIERTA. SIN EMBARGO, ESTA ADVERTENCIA SE

APLICA A TODOS LOS PRODUCTOS DE COCCIÓN A GAS.

IMPORTANT: Keep for Local Inspector (cont)/IMPORTANT : À conserver pour l’inspecteur local (suite)/
IMPORTANTE: Guarde esta información para el inspector local (cont.)

DÉGAGEMENTS

La cuisinière peut être installée avec un dégagement nul contre des matériaux combustibles à l’arrière et sur les côtés en dessous de la table
de cuisson. Pour des renseignements complets concernant l’installation des armoires au-dessus de la cuisinière et les dégagements aux
parois combustibles au-dessus de la surface de cuisson, consultez les schémas sur l’installation. Pour des RAISONS DE SÉCURITÉ, n’installez
pas une cuisinière dans des armoires en matériaux combustibles non conformes aux schémas de l’installation.

* REMARQUE : La dimension de 76,2 cm (30 po) entre la surface de cuisson et les armoires murales présentées sur l’illustration ne concerne pas les
cuisinières avec un four surélevé ou un micro-ondes. Les instructions d’installation du four surélevé précisent la dimension minimale acceptable
entre la surface de cuisson et le four surélevé. La dimension de 76,2 cm (30 po) peut être réduite à pas moins de 61 cm (24 po) lorsque les armoires
murales d’une résidence sont protégées par des matériaux ignifuges conformément aux normes de l’American National Standards – National Fuel
Gas Code (Code national des combustibles gazeux), ou lorsque les armoires murales d’une maison mobile sont protégées par des matériaux
ignifuges selon la norme fédérale : Mobile Home construction and Safety (norme de sécurité et de construction des maisons mobiles).

Pour éliminer le risque de brûlure ou d’incendie, en passant la main au-dessus des éléments de surface chauffés, l’espace de rangement dans les
armoires situées au-dessus des éléments de surface doit être évité. Si une armoire de rangement existe, le risque peut être réduit en installant
une hotte d’extraction qui dépasse horizontalement d’un minimum de 13 cm (5 po) de la partie inférieure des armoires.

DIMENSIONES DE LOS ESPACIOS DE DESPEJE

Esta estufa se puede instalar sin espacios de despeje contra superficies combustibles en la parte trasera y a los costados de la misma por
debajo de la cubierta. Para obtener información completa sobre la instalación de los armarios sobre la cubierta y los espacios de despeje
para las paredes combustibles sobre la cubierta vea las figuras de instalación. Por RAZONES DE SEGURIDAD, no instale una estufa en ninguna
ubicación con armarios combustibles que no concuerden con las figuras de instalación.

* NOTA: El despeje de 30 pulgadas (76,2 cm) entre la cubierta de cocción y el armario que se muestra en la figura no se aplica a las estufas
con hornos elevados o a los microondas. Las instrucciones de instalación del horno elevado especificarán el espacio mínimo entre la cubierta
y el horno elevado. El despeje de 30 pulgadas (76,2 cm) puede ser reducido a no menos de 24 pulgadas (61 cm) cuando los armarios del hogar
están protegidos con materiales a prueba de fuego de acuerdo con las Normas Nacionales de Estados Unidos (ANS) y el Código Nacional de Gas
o en las casas rodantes cuando las mismas están protegidas con materiales a prueba de fuego de acuerdo con la Norma Federal de Construcción
y Seguridad de Viviendas Móviles.

Para eliminar el riesgo de quemaduras o de incendios cuando se intenta alcanzar algún objeto sobre los elementos superiores, evite almacenar
artículos en los armarios que están sobre la estufa. Si se instala un armario sobre la cubierta, se puede reducir el riesgo instalando una campana
de ventilación que se proyecte horizontalmente en un mínimo de 5 pulgadas (13 cm) más allá de la base de los armarios.

W A R N I N G / A V E R T I S S E M E N T / A D V E R T E N C I A

Summary of Contents for JGS8750BDB

Page 1: ...sez ces instructions avec l appareil INSTALADOR Deje estas instrucciones con el electrodoméstico Jenn Air Updraft Gas Slide In Range Installation Instructions Instructions d installation Instrucciones de Instalación Cuisinière à gaz encastrable à circulation ascendante Jenn Air Estufa deslizante a gas de corriente ascendente Jenn Air ...

Page 2: ...be installed to engage the RIGHT rear leveling foot Install the bracket as shown in step 2 MOBILE HOMES The installation of a range designed for mobile home installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 or when such standard is not applicable th...

Page 3: ...rawer Your range may not be equipped with some of the features referred to in this manual Gas Supply Installation of this range must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 latest edition In Canada the range must be installed in accordance with the current CGA Standard CAN CGA B149 Installation Codes for Gas Burning Appliances and Equip...

Page 4: ...EMENT au mur ou au sol Le support doit être installé afin de retenir le pied de mise à niveau arrière DROIT Installez le support comme il est indiqué en étape 2 MAISONS MOBILES L installation d une cuisinière conçue pour une maison mobile doit être conforme à la Manufactured Home Construction and Safety Standard norme de sécurité et de construction des résidences préfabriquées titre 24 CFR partie ...

Page 5: ...ent Votre cuisinière peut ne pas être équipée de certaines caractéristiques mentionnées dans ce manuel Alimentation En Gaz L installation de cette cuisinière doit être conforme aux codes locaux ou en l absence de tels codes conforme au National Fuel Gas Code ANSI Z223 1 édition la plus récente Au Canada la cuisinière doit être installée conformément à la norme de l ACG CAN ACG B149 Codes d install...

Page 6: ...una estufa diseñada para su instalación en casas rodantes debe hacerse de acuerdo con la Norma de Construcción y Seguridad de Viviendas Prefabricadas Manufactured Home Construction and Safety Standard Título 24 CFR Parte 3280 anteriormente la Norma Federal de Construcción y Seguridad de Viviendas Prefabricadas Título 24 Parte 280 o cuando dicha norma no se aplique con la Norma de Instalación en Vi...

Page 7: ...ás del cajón de almacenamiento Es posible que esta estufa no venga equipada con todas las características que se indican en este manual Suministro de gas La instalación de esta estufa debe hacerse de acuerdo con los códigos locales o en ausencia de ellos con el Código Nacional de Gas ANSI Z223 1 última edición En Canadá esta estufa debe instalarse de acuerdo con la Norma CGA vigente CAN CGA B149 C...

Page 8: ...protected with fireproof materials in accordance with American National Standards National Fuel Gas Code or in mobile homes when they are protected with fireproof materials in accordance with the Federal Standard for Mobile Home Construction and Safety To eliminate the risk of burns or fire by reaching over heated surface units cabinet storage space located above the surface units should be avoide...

Page 9: ...à pas moins de 61 cm 24 po lorsque les armoires murales d une résidence sont protégées par des matériaux ignifuges conformément aux normes de l American National Standards National Fuel Gas Code Code national des combustibles gazeux ou lorsque les armoires murales d une maison mobile sont protégées par des matériaux ignifuges selon la norme fédérale Mobile Home construction and Safety norme de séc...

Page 10: ...o withstand the heat produced by the normal safe operation of a self clean range Discoloration or delamination may occur To avoid possible damage we recommend increasing the 30 cabinet opening to 31 1 4 minimum and using heat shield CABKIT V The countertop cut out must remain 30 ATTENTION Certaines armoires de couleur blanche et de style européen sont équipées de façades de porte et de tiroir en v...

Page 11: ...les Mount ANTI TIP bracket to wall or floor with 2 screws Percez des trous de 1 8 po 3 mm Installez le support ANTIRENVERSEMENT au mur ou au sol avec deux vis Taladre agujeros de 1 8 3 mm Instale el soporte ANTIVUELCO en la pared o en el piso usando 2 tornillos Included Compris Se incluye Not Included Non inclus No se incluye Tools Needed Outils nécessaires Herramientas Necesarias If you have LP p...

Page 12: ...pipe thread compound approved for LP gas to all threads Always hold the regulator in stable position while attaching gas supply line Appliquez sur tous les filetages un composé à joints approuvé pour le GPL Tenez toujours le détendeur en position stable lors du raccordement de la conduite d alimentation en gaz Aplique compuesto para roscas de tuberías aprobado para gas LP a todas las roscas Siempr...

Page 13: ...lugar definitivo Instalador tenga cuidado de no dañar el piso No incline la estufa de lado a lado se podría dañar el marco del borde 11 Gas À gaz Gas Electric Électrique Eléctrica Make sure flexible connector and electrical cord are not kinked Assurez vous que le raccord flexible et le cordon d alimentation ne sont pas entortillés Asegúrese de que el conector flexible y el cordón eléctrico no esté...

Page 14: ...ME BLEUE SE SOULEVANT Fermez l obturateur pour rectifier AZUL QUE SE SEPARA DEL QUEMADOR Cierre el obturador para corregir la situación Flame Adjustment Réglage de la flamme Ajuste de la llama Check oven burners for distinct inner blue flame Vérifiez les brûleurs de four pour voir une flamme bleue interne distincte Verifique que el interior de la llama de los quemadores del horno sea azul ...