background image

JENN-AIR

®

 DETAILED PLANNING DIMENSIONS

JENN-AIR

®

 DETAILED PLANNING DIMENSIONS

2 of 3

8560BdZw815

IMPORTANT:

 Dimensional specifications are provided for planning purposes only.  

Do not make any cutouts based on this information.

 Refer to the Installation Guide 

before

 

selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.  
All Jenn-Air

®

 appliances are appropriately UL, CUL or CSA approved.

D*

G

E

A

B

B

I

K

J

H

C

e

F

Side

Cabinet

H

D*

G

I**

K

J**

E

C

e

B

B

H

F

H

Side

Cabinet

A

D*

G

I**

K

J**

E

C

e

B

B

H

F

H

Side

Cabinet

A

MODEL #

JEC3536B

in

cm

A

Width of combustible area above 
cooking surface (min.)

36

91.4

B

Width from cooktop to fixed wall or 
other combustible material (min.)

1

2.5

C

Width to outer edge of outlet (max.)

9

23.0

D*

Height to bottom of uncovered wood or  
metal cabinet above cooking surface (min.)

30

76.2

E

Height to bottom of uncovered wood or 
metal cabinet (min.)

18

45.7

F

Height to top edge of outlet (min.)

7

17.8

G

Depth of upper cabinet

13

33.0

H

Depth from cutout to wall (min.)

1

2.5

I

Width of cutout

35

1

2

90.2

J

Depth of cutout

20

1

2

52.0

K

Depth from cutout to front of countertop

2

5

8

6.7

e

Recommended electrical access location 

* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal 

cabinet is covered by not less than 

1

4

" (0.6 cm) flame retardant millboard 

covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) 
stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.

   If installing a hood or microwave hood combination above the cooktop, 

follow the hood or microwave hood combination instructions for 
dimensional clearances above the cooking surface.

OPENING/CLEARANCE DIMENSIONS

FRONT VIEW

TOP VIEW

SIDE VIEW

36" ELECTRIC RADIANT COOKTOP

JEC3536BS – 36

7

16

" x 5

5

16

" x 22

3

16

JEC3536BB – 36

5

16

" x 5

5

16

" x 21

11

16

"

ELECTRICAL REQUIREMENTS

A 3-wire or 4-wire, single phase, 120/240 volt, 60 Hz., AC only electrical 

supply is required on a separate, 40-amp circuit fused on both sides of 
the line. 48" (121.9 cm) of 

1

2

" (1.3 cm) I.D. flexible cable is provided.

LOCATION REQUIREMENTS

•   To ensure cooktop base clearance, cabinet side walls need to be wider 

than the cutout. 

•  If cabinet has a drawer, allow a 5

1

2

" (14.0 cm) minimum clearance 

between countertop and top of drawer. 

COOKTOP OVER SINGLE WALL OVEN INSTALLATION 

REQUIREMENTS

•  For approved model number combinations, refer to the under counter 

label on the bottom of the cooktop burner box.

• To install a cooktop over a single wall oven, refer to page 3.