Installation of LP Orifice Spuds

Figure 6

B. Invert Cap in Appliance Pressure Regulator

(See figures 7 and 8.) With the appliance installed, the
regulator is located on the underside of the burner box
on the right hand side at the inlet to the gas manifold.
Identify the make of appliance regulator on the unit and
follow the instructions in the appropriate illustration.

Figure 7: Conversion of Maxitrol

Appliance Pressure Regulator

With a quarter, engage slot and rotate cap 1/8 of a turn
counterclockwise. To remove cap, turn cap over and
reinstall.

Figure 8: Conversion of Harper-Wyman

Appliance Pressure Regulator

After conversion, steps A and B have been completed,
check the appearance of each burners’ flame at the

Hi

and

Lo

settings against figure 9. If the flames appear too large

or too small, review all steps to make sure they were
completed correctly.

Figure 9: Flame Appearance at

Hi

and

Lo

Summary of Contents for EXPRESSIONS CVGX2423B

Page 1: ...a side clearance of at least 6 is recommended for optimum ventilation SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE IMPORTANT Installation should be performed only by a Jenn Air Authorized Servicer or...

Page 2: ...ones se muestran en pulgadas y cent metros SELECCIONE EL CORTE ADECUADO DE DUCTOS VEA LAS INSTRUCCIONES DE LOS DUCTOS LAS DIMENSIONES DEL HUECO SON IMPORTANTES IMPORTANTE 53 66 cm 21 1 8 pulg 86 68 cm...

Page 3: ...o eliminate potential hazard of reaching over open flames Preparation Of Countertop The cutout in the countertop into which the appliance is to be installed should be prepared according to the cutout...

Page 4: ...enciales al tratar de alcanzar algo por encima de las llamas encendidas Preparaci n del mostrador El hueco del mostrador de la cocina en el que se instalar el electrodom stico deber prepararse de acue...

Page 5: ...Connecting Appliance To Gas Supply A QUALIFIED SERVICEMAN OR GAS APPLIANCE INSTALLER MUST MAKE THE GAS SUPPLY CONNECTION Leak testing of the appliance shall be conducted by the installer according to...

Page 6: ...ALIZARLA UN T CNICO CALIFICADO DE SERVICIO O UN INSTALADOR DE ELECTRODOM STICOS DE GAS Las pruebas de fugas del electrodom stico deber realizarlas el instalador de acuerdo con las instrucciones propor...

Page 7: ...ween 6 and 14 inches of water column or if converted for LP gas between 11 and 14 inches Connecting Appliance To Electricity ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three p...

Page 8: ...o al suministro el ctrico INSTRUCCIONES EL CTRICAS DE CONEXI N A TIERRA Este electrodom stico est equipado con una clavija de conexi n a tierra de tres puntas para protegerlo contra el peligro de desc...

Page 9: ...ift nut driver out of burner throat Orifice spud should be captured in the recess Repeat this step for each burner Step 5 Locate the LP orifice spud packet taped to the underside of the burner box The...

Page 10: ...l paquete del puntal del orificio LP adherido por debajo de la caja del quemador Los puntales tienen n meros peque os estampados en un lado Este n mero codifica el di metro del orificio y la ubicaci n...

Page 11: ...propriate illustration Figure 7 Conversion of Maxitrol Appliance Pressure Regulator With a quarter engage slot and rotate cap 1 8 of a turn counterclockwise To remove cap turn cap over and reinstall F...

Page 12: ...t figure 9 If the flames appear too large or too small review all steps to make sure they were completed correctly Installation of Natural Gas Orifice Spuds This appliance is equipped for electronic a...

Page 13: ...en pouces S LECTIONNER L OUVERTURE QUI CONVIENT POUR LE CONDUIT VOIR LES INSTRUCTIONS RELATIVES AU CONDUIT RESPECTER IMP RATIVEMENT LES DIMENSIONS DE LA D COUPE INSTRUCTIONS DE MISE EN SERVICE OPTION...

Page 14: ...r paration du comptoir La d coupe o sera ins r e la plaque de cuisson dans le comptoir doit tre pr par e aux dimensions fournies la page 1 de cette notice explicative ATTENTION Le respect des dimensio...

Page 15: ...ENTATION EN GAZ DOIT TRE EFFECTU PAR UN TECHNICIEN QUALIFI OU UN INSTALLATEUR D APPAREILS GAZ L installateur va v rifier la pr sence de fuites sur l appareil en suivant les consignes ci jointes 1 Inst...

Page 16: ...rdement de la plaque de cuisson l lectricit INSTRUCTIONS DE MISE LA TERRE Cette plaque de cuisson est munie d une fiche trois broches pour permettre la mise la terre et prot ger l utilisateur contre l...

Page 17: ...aque br leur 5 Prendre le paquet de bouchons orifices pour GPL coll sous le compartiment des br leurs Les bouchons orifices ont des chiffres estamp s sur le c t Ce chiffre est un code qui correspond a...

Page 18: ...BORDES DEL DISCO PARA QUITAR EL TAP N Y EL PASADOR APLIQUE PRESI N LATERAL CON LOS DEDOS A LOS BORDES DEL DISCO PARA COLOCAR DE NUEVO EL TAP N Y EL PASADOR Con una moneda de 25 centavos inserte la ran...

Page 19: ...E C T REMETTRE LA TIGE DANS LE CAPUCHON EN POUSSANT SUR LES BORDS DU DISQUE DU BOUT DES DOIGTS Ins rer une pi ce de 25 sous dans la fente du capuchon et le faire tourner de 1 8 de tour dans le sens co...

Page 20: ...seguido todos los pasos correctamente Instalaci n de los puntales de orificio de gas natural Este electrodom stico est equipado con un reencendido autom tico por medio de un encendedor de chispa que...

Page 21: ...ectu es correctement Pose des bouchons orifices pour gaz naturel Cette plaque de cuisson est quip e d un syst me lectronique qui allume le gaz en produisant une tincelle et se trouve sur le c t de cha...

Reviews: