Gas Supply Line

Provide a gas supply line of ¾" (1.9 cm) rigid pipe to 

the range location. A smaller size pipe on longer runs 

may result in insufficient gas supply. With LP gas, piping 

or tubing size can be ½" (1.3 cm) minimum. Usually, LP 

gas suppliers determine the size and materials used in 

the system.
NOTE: Pipe-joint compounds that resist the action  

of LP gas must be used. Do not use TEFLON

®†

 tape.

Flexible Metal Appliance Connector:

 

If local codes permit, a new CSA design-certified,  

4–5 ft (122–152.4 cm) long, 

5

8

" (1.6 cm) or ¾" (1.9 cm) 

I.D. flexible metal appliance connector may be used  

for connecting range to the gas supply line.

 

A ½" (1.3 cm) male pipe thread is needed for connection 

to the female pipe threads of the inlet to the range 

pressure regulator.

 

Do not kink or damage the flexible metal tubing 

when moving the range.

IMPORTANT: All connections must be wrench-tightened. 

Do not make connections to the gas regulator too tight. 

Making the connections too tight may crack the regulator 

and cause a gas leak. Do not allow the regulator to turn or 

move when tightening fittings.

 

Must include a shut-off valve:
The supply line must be equipped with a manual shut-off 

valve. This valve should be located in the same room but 

external to the range opening such as an adjacent cabinet. 

It should be in a location that allows ease of opening and 

closing. Do not block access to shut-off valve. The valve  

is for turning on or shutting off gas to the range.

A.  Gas supply line
B.  Shut-off valve “open” position
C.  To range

A

B

C

†®TEFLON is a registered trademark of Chemours.

Gas Pressure Regulator 

The gas pressure regulator supplied with this range must be 

used. The inlet pressure to the regulator should be as follows 

for proper operation:
Natural Gas:
Minimum pressure: 6" (15.2 cm) WCP
Maximum pressure: 14" (35.6 cm) WCP
LP Gas:
Minimum pressure: 11" (27.9 cm) WCP
Maximum pressure: 14" (35.6 cm) WCP
Contact local gas supplier if you are not sure about 

the inlet pressure.

Burner Input Rating – Altitude

Input ratings shown on the model/serial/rating plate are for 

elevations up to 2,000 ft (609.6 m).
For elevations above 2,000 ft (609.6 m), ratings are reduced  

at a rate of 4% for each 1,000 ft (304.8 m).

Gas Supply Pressure Testing

Gas supply pressure for testing regulator must be at least 1" 

(2.5 cm) water column pressure above the manifold pressure 

shown on the model/serial/rating plate.
Line Pressure Testing Above ½ psi Gauge (14" WCP)
The range and its individual shut-off valve must be 

disconnected from the gas supply piping system during 

any pressure testing of that system at test pressures in 

excess of ½ psi (3.5 kPa).
Line Pressure Testing at ½ psi Gauge (14" WCP) or Lower
The range must be isolated from the gas supply piping 

system by closing its individual manual shut-off valve during 

any pressure testing of the gas supply piping system at test 

pressures equal to or less than ½ psi (3.5 kPa).

Summary of Contents for 8284756

Page 1: ...NSTALLATION REQUIREMENTS 4 Tools Parts 4 Location Requirements 6 Electrical Requirements 8 Gas Supply Requirements 8 INSTALLATION INSTRUCTIONS 10 Unpack the Range 10 Install Anti Tip Bracket 11 Make G...

Page 2: ...property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to lig...

Page 3: ...to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage the anti tip bracket if the range is moved Do not operate r...

Page 4: ...any tools listed here Pipe wrench Adjustable wrench or 5 8 wrench Z x 41 4 flat blade screwdriver 2 Phillips screwdriver Drill C drive ratchet ZB zn combination wrench Pliers Level Tubing cutter Z v C...

Page 5: ...bustible material such as tile or stainless steel See Cabinet Dimensions in the Location Requirements section for installation requirements 30 76 2 cm Adjustable Backguard Order Part Number 8285148 36...

Page 6: ...r carpet and under range if installing range over carpeting IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier to make sure that the materials used will not discolo...

Page 7: ...cabinet width C 13 33 cm max upper cabinet depth D For minimum clearance to top of range E 30 76 8 cm on 30 76 2 cm models 36 92 1 cm on 36 91 4 cm models 48 122 6 cm on 48 121 9 cm models F 6 15 2 c...

Page 8: ...Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating per...

Page 9: ...nd closing Do not block access to shut off valve The valve is for turning on or shutting off gas to the range A Gas supply line B Shut off valve open position C To range A B C TEFLON is a registered t...

Page 10: ...tion 2 a Remove kick plate from top of range and grate pack Unpack the Range In packaging Packaging removed A A Kick plate A A Kick plate b Lay kick plate to the side to avoid scratching the stainless...

Page 11: ...Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of t...

Page 12: ...as pressure regulator B Use pipe joint compound C Adapter must have male pipe thread D Flexible connector E Manual gas shut off valve F or gas pipe G Use pipe joint compound H Adapter Verify Anti Tip...

Page 13: ...r to the Use and Care Guide A Griddle drip tray B Griddle A B Electronic Ignition System Install Burner Bases and Burner Caps Install the burner base making sure the igniter electrode is properly alig...

Page 14: ...1 Unplug range or disconnect power 2 Remove burner grates 3 Remove the control knobs 4 Open the oven door and remove the 2 screws on each side of the range that hold the control console in place NOTE...

Page 15: ...rough the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 For oven use and cleaning read the Use and Care Guide Check Operati...

Page 16: ...W10821591B 3 16 TM 2016 Jenn Air All rights reserved Used under license in Canada TM 2016 Jenn Air Tous droits r serv s Utilis sous licence au Canada...

Reviews: