Jenn-Air 8284756 Installation Instructions Manual Download Page 11

11

A

B

C

A. Centerline

B.  Centerline of cutout to outside 

edge of anti-tip bracket

C. Back wall to back of range

3.  Drill two ¹⁄

8

" (3.0 mm) holes that correspond to the 

bracket holes of the determined mounting method. 

See the following illustrations.
Floor Mounting

B

A

A. #12 x 1

5

8

" screws

B. Anti-tip bracket

Wall Mounting

B

A

A. #12 x 1

5

8

" screws

B. Anti-tip bracket

4.  Using a Phillips screwdriver, mount anti-tip bracket to 

the wall or floor with the two #12 x 1

5

8

" screws provided.

Depending on the thickness of your flooring, longer 

screws may be necessary to anchor the bracket to 

the subfloor. Longer screws are available from your 

local hardware store.

5.  Move range close enough to opening to allow for 

electrical connections to be made. Remove shipping 

base, cardboard, or hardboard from under range.

6.  Continue installing your range using the following  

installation instructions.

Install Anti-Tip Bracket

WARNING

Tip Over Hazard

A child or adult can tip the range and be killed.
Install anti-tip bracket to floor or wall per installation 

instructions.
Slide range back so rear range foot is engaged in the 

slot of the anti-tip bracket.
Re-engage anti-tip bracket if range is moved.
Do not operate range without anti-tip bracket installed 

and engaged.
Failure to follow these instructions can result in death 

or serious burns to children and adults.

1.  Determine which mounting method to use: floor or wall.

If you have a stone or masonry floor, you can use the wall 

mounting method.

2.  Determine and mark centerline of the cutout space. 

The mounting bracket must be installed on the right 

side of the cutout. Position mounting bracket in cutout 

as shown in the following illustration.
Measurement B:
30" (76.2 cm) ranges: 14

1

4

" (36.1 cm)

36" (91.4 cm) ranges: 17

1

4

" (43.8 cm)

48" (121.9 cm) ranges: 23

3

8

" (59.3 cm)

Measurement C:
Optional distance from back wall. If back wall is constructed 

of a combustible material and a backguard is not installed, 

a 6" (15.2 cm) minimum clearance is required for all models. 

Install anti-tip bracket accordingly.

Summary of Contents for 8284756

Page 1: ...NSTALLATION REQUIREMENTS 4 Tools Parts 4 Location Requirements 6 Electrical Requirements 8 Gas Supply Requirements 8 INSTALLATION INSTRUCTIONS 10 Unpack the Range 10 Install Anti Tip Bracket 11 Make G...

Page 2: ...property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to lig...

Page 3: ...to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of the anti tip bracket Re engage the anti tip bracket if the range is moved Do not operate r...

Page 4: ...any tools listed here Pipe wrench Adjustable wrench or 5 8 wrench Z x 41 4 flat blade screwdriver 2 Phillips screwdriver Drill C drive ratchet ZB zn combination wrench Pliers Level Tubing cutter Z v C...

Page 5: ...bustible material such as tile or stainless steel See Cabinet Dimensions in the Location Requirements section for installation requirements 30 76 2 cm Adjustable Backguard Order Part Number 8285148 36...

Page 6: ...r carpet and under range if installing range over carpeting IMPORTANT To avoid damage to your cabinets check with your builder or cabinet supplier to make sure that the materials used will not discolo...

Page 7: ...cabinet width C 13 33 cm max upper cabinet depth D For minimum clearance to top of range E 30 76 8 cm on 30 76 2 cm models 36 92 1 cm on 36 91 4 cm models 48 122 6 cm on 48 121 9 cm models F 6 15 2 c...

Page 8: ...Securely tighten all gas connections If connected to LP have a qualified person make sure gas pressure does not exceed 14 36 cm water column Examples of a qualified person include licensed heating per...

Page 9: ...nd closing Do not block access to shut off valve The valve is for turning on or shutting off gas to the range A Gas supply line B Shut off valve open position C To range A B C TEFLON is a registered t...

Page 10: ...tion 2 a Remove kick plate from top of range and grate pack Unpack the Range In packaging Packaging removed A A Kick plate A A Kick plate b Lay kick plate to the side to avoid scratching the stainless...

Page 11: ...Tip Over Hazard A child or adult can tip the range and be killed Install anti tip bracket to floor or wall per installation instructions Slide range back so rear range foot is engaged in the slot of t...

Page 12: ...as pressure regulator B Use pipe joint compound C Adapter must have male pipe thread D Flexible connector E Manual gas shut off valve F or gas pipe G Use pipe joint compound H Adapter Verify Anti Tip...

Page 13: ...r to the Use and Care Guide A Griddle drip tray B Griddle A B Electronic Ignition System Install Burner Bases and Burner Caps Install the burner base making sure the igniter electrode is properly alig...

Page 14: ...1 Unplug range or disconnect power 2 Remove burner grates 3 Remove the control knobs 4 Open the oven door and remove the 2 screws on each side of the range that hold the control console in place NOTE...

Page 15: ...rough the steps to see which step was skipped 2 Check that you have all of your tools 3 Dispose of recycle all packaging materials 4 For oven use and cleaning read the Use and Care Guide Check Operati...

Page 16: ...W10821591B 3 16 TM 2016 Jenn Air All rights reserved Used under license in Canada TM 2016 Jenn Air Tous droits r serv s Utilis sous licence au Canada...

Reviews: