INSTALLER FINAL CHECK
Specified clearance maintained 18” from
combustible materials.
All internal packaging has been removed.
The gas supply shut off valve has been
located.
Model 710-0036-LP
The hose and regulator are properly
connected.
The unit has been tested and is free of
leaks.
WARNING
1. Do not store a spare LP gas cylinder under or near this appliance.
2. Never fill the cylinder beyond 80 percent capacity.
3. If the information above is not followed exactly, a fire causing death or serious injury could occur.
Model 710-0037-NG
WARNING
The outdoor cooking gas appliance and its individual shutoff valve must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressure in excess of ½
psi (3.5 kpa).
1. The outdoor cooking gas appliance must be isolated from the gas supply piping system by closing
its individual manual shutoff valve during any pressure testing of the gas supply piping system at
test pressures equal to or less ½ psi (3.5 kpa).
11