7
Ideal location for a CO detector
Space without air circulation. If the detector is installed on the wall, it must be installed
At least 15 cm from the ceiling.
Above the level
Top of doors
And windows
Between 1 and 3m depending on
Of the potential source of CO
180 cm
Less than
ground
At least 30 cm
Of any obstacle
15 cm
at least
In the room where the combustion appliance is located: The detector must be
placed Between 1 and 3 m horizontally from the potential source of CO, to at least
1.80 of the soil And 15cm from the ceiling. In the rooms to be lived: relatively close
to the space where Breathe the occupants
At the highest spot of an attic room
In places where temperature can drop under 5C (or 41F) or exceed 45C (113F)
Close to a steam or dust source, in a dirty or insect infested room.