INITIAL INSPECTION AND ASSEMBLY   

 

 

Carefully unpack the instrument and accessories. Inspect for 
damages made in shipment. If any damage is found, notify your 
Jenco representative immediately. All packing materials should 
be saved until satisfactory operation is confirmed. 

 

BEFORE YOUR FIRST USE   

 

 

A.    Replace the Batteries

 

 

Replace the battery when the blinking 
low battery indicator “BAT ” appears on 
the middle left hand side of the LCD 
screen. The instrument can operate 
within specifications for 
approximately2~3 hours after low battery 
indicator appears. 
 

1. Shown in the right figure. 
2. Take off the battery cover. 
3. Remove all of the old batteries and 

insert a new set of batteries ensuring 
the polarities are correct.

 

 

B.    Soak the Electrode 

1.    Remove the electrode cap covering the VisionPlus pH 

meter. 

 

2.    Soak the electrode in a 3M KCL solution for 2 hours 

before first use or after storage. 

 

C.    Setup and Calibrate the Electrode and Meter

 

VisionPlus pH 618N must be setup and calibrated before your 
first use.    Please follow the instructions detailed in section 

USING VISIONPLUS pH 618N

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 

1

2

Summary of Contents for VisionPlus pH618N

Page 1: ...Operation Manual MODEL pH 618N Microcomputer Based pH Temperature Pocket Meter pH618N...

Page 2: ...ption 3 B VisionPlus Graphical Display 3 OPERATION MODES AND KEYPAD OPERATIONS 4 A Operation Modes 4 B Keypad Operations 4 USING VISIONPLUS pH 618N 5 A Power ON OFF 5 B Set Date and Time 5 C Select Bu...

Page 3: ...nstrument can operate within specifications for approximately2 3 hours after low battery indicator appears 1 Shown in the right figure 2 Take off the battery cover 3 Remove all of the old batteries an...

Page 4: ...r 5 Electrode ATC assembly Electrode cap is not shown B VisionPlus Graphical Display 1 DATE MM DD YY 2 HOLD mode indicator 3 MEASURE mode indicator 4 CALIBRATION buffer s 5 TIME HH MM 24H format 6 pH...

Page 5: ...et Mode is used to change date and time 6 Buffer Select Mode Buffer Select Mode is used to select the buffer set which can either be 7 00 7 00 4 01 10 01 or 6 86 6 86 4 00 9 18 B Keypad Operations Key...

Page 6: ...d Scrolls through stored data Date and Time Set 0 second Decreases current number SCROLL Buffer Select 0 second Selects new buffer set USING VISIONPLUS pH 618N A Power ON OFF Press HOLD key for 2 seco...

Page 7: ...H meter will perform end point sensing to determine when the calibration reading is stable Meter is calibrated when WAIT icon disappears and the unit will automatically enter the next point calibratio...

Page 8: ...E and M XX icons will appear indicating the reading has been saved and stored in memory location XX The unit will automatically returns to Measure Mode and ready to perform other task Note The Model p...

Page 9: ...trode ATC assembly as shown in the right figure 2 Remove the old electrode from the electrode collar 3 Insert a new electrode make sure the electrode fit back into the meter correctly 4 Screw back the...

Page 10: ...0 00 to14 00pH range Over Range or Recalibrate OVER 0 0 60 0 C pH CAL a pH STAND b pH SLOPE a Offset 7 00pH mV 90mV Offset 6 86pH mV 98 3mV b New slope ideal slope by 30 Use a new buffer solution Repl...

Page 11: ...Electrode Slope recognition 30 at pH 4 00 4 01 9 18 and 10 01 Input impedance 1012 Temperature Temperature sensor Thermistor 10 k at 25 C Temperature unit Default in factory General Power Meter LR44...

Page 12: ...protection items must be carefully packed to prevent damage in shipment and insured against possible damage or loss Jenco will not be responsible for damage resulting from careless or insufficient pa...

Page 13: ...618N TC CHEN 2008 7 20 K618N 01 2009 4 3 02 2009 4 3 01 618 MANUAL 618 09 01 14 P2 09 4 3 P2 5 P8 P10 P11 BAT 09 4 15 3M KCL FOR 2 HOURS...

Reviews: