JENCO 3177MB Operation Manual Download Page 19

18

SPECIFICATIONS

Display

Range

Resolution

Accuracy

Conductivity

K=0.1 : 0.00 to 99.99

μ

S/cm

100.0 to 200.0

μ

S/cm

K=0.475: 0.0 to 474.9

μ

S/cm

475 to 4749

μ

S/cm

4.75 to 47.49 mS/cm

47.5 to 200.0 mS/cm

0.01

μ

S/cm,

0.1

μ

S/cm,

1

μ

S/cm,

0.01 mS/cm,

0.1 mS/cm

±0.5% F.S.

TDS

K=0.1 : 0.00 to 99.99 mg/L

100.0 to 200.0 mg/L

K=0.475: 0.0 to 474.9 mg/L

475 to 4749 mg/L

4.75 to 47.49 g/L

47.5 to 200.0 g/L

0.01 mg/L,

0.1 mg/L,

1 mg/L,

0.01 g/L,

0.1 g/L

±0.5% F.S.

Salinity

0.0 to 80.0 ppt

0.1 ppt

±0.5% F.S.

Temperature

-10.0 to 120.0 °C

0.1 °C

±0.2 °C

Conductivity calibration

1 point

Reference Temperature

15.0 to 25.0 °C, default at 25.0 °C

Temperature Coefficient

0.0% to 4.0%, default at 1.91%

TDS Factor

0.30 to 1.00, default at 0.65

Cell Constant

0.10 (2 wire), 0.475 (4 wire)

Temperature sensor

Thermistor, 10 k

Ω

at 25 °C

Connectivity

Bluetooth

Calibration Back-up

EEPROM

Memory

750 sets

Audio Feedback

All Touch Keys

Screen

Segmented LCD w/backlight

Power

6 X 1.5 V AAA Batteries or 100 to

240 V AC adapter

Ambient Temperature Range

0 to 50 °C

Relative Humidity

up to 90%

Case

IP 54

Dimensions (W x D x H)

150 x 210 x 45 mm

Weight

430 grams

Summary of Contents for 3177MB

Page 1: ...Operation Manual MODEL 3177MB Cond TDS Salt Temperature Based Bluetooth Benchtop Meter 3177MB...

Page 2: ...splay 4 B Operational Keys Description 5 MODES OF THE METER 6 OPERATIONAL PROCEDURES 7 A Calibration 7 B Conductivity Salinity TDS Measurements 9 C Save Recall And Delete Data 10 D Preparing Conductiv...

Page 3: ...icators The unit prompts the user through calibration and measurement procedures The unit is also equipped with a non volatile memory allowing the user to store 750 different sets of readings This uni...

Page 4: ...fter unlocking the screw take off the battery cover Fig 1 2 Replace the old batteries with new ones and install them on the correct polarity position 3 Put the battery cover back on the meter Use a Ph...

Page 5: ...ndicates Salinity measurement 3 uS cm Microsiemens indicates Conductivity measurement 9 CELL K Indicates conductivity cell constant value 4 CAL This will be displayed when the unit enters into the cal...

Page 6: ...ternal memory In the Recall and Delete modes press Mode Clear key to exit Recall and Delete modes respectively 3 Power BLE Bluetooth Press and hold this key for 2 seconds to power on and shut off the...

Page 7: ...ES and no for data all delete In the Delete One mode view to be deleted data and data site numbers by pressing these keys MODES OF THE METER This instrument has six modes as follow 1 Conductivity mode...

Page 8: ...rature Coefficient Temperature Reference Probe Basic Cell Constant Standard Solutions Calibration and K Value Input To access these sections 1 Turn the unit on In the conductivity TDS salinity mode pr...

Page 9: ...e is 1 91 To change the Temperature Coefficient use the Up or Down keys to adjust the value between 0 00 to 4 00 Press Enter key to save the new value and go to the next calibration parameter Temperat...

Page 10: ...tant to a known value by pressing the Up or Down keys You can now input the K value from 70 to 130 of the probe basic cell constant Press the Enter key to exit calibration and return to normal operati...

Page 11: ...a a Press Mode Clear key until the dEL onE or dEL ALL shows Then press the Enter key to go into the corresponding Delete one or Delete ALL mode b In the Delete ALL mode press the Enter and enters the...

Page 12: ...prepared APP NAVIGATION A App Functions The 3177MB is a conductivity salinity TDS temperature Bluetooth benchtop meter with iOS and Android apps for tablets Functions of the App includes graphing gui...

Page 13: ...7MB is connected to the tablet the device Bluetooth light will blink slowly After the App has been installed calibrate the 3177MB to ensure the best reading quality D Measurement Screen The Measure Sc...

Page 14: ...ata From this screen tap the Calibrate button and follow the step by step instructions to calibrate the 3177MB Fig 2 G Settings Screen The Settings Screen displays the various settings that affects th...

Page 15: ...rmation c From the saved reading detail screen tap the Notes field to add notes d Tap the button to save and exit the detail screen 6 Share and print saved readings a Tap the Saved tab in the navigati...

Page 16: ...d Wait for the App to discover the 3177MB e Tap the Connect button I Notes 1 One meter can be paired to only one App at a time To put an already paired meter into pairing mode one must first close the...

Page 17: ...olled environment This device and its antenna must not be co located or operating in conjunction with any other antenna or transmitter To comply with FCC RF exposure compliance requirements this grant...

Page 18: ...t K constant value input 1 Sample cannot be tested 2 Decontaminate clean cell or replace cell 3 Input correct K value over during calibration 10 0 to 120 0 1 Incorrect standard solution 2 Conductivity...

Page 19: ...80 0 ppt 0 1 ppt 0 5 F S Temperature 10 0 to 120 0 C 0 1 C 0 2 C Conductivity calibration 1 point Reference Temperature 15 0 to 25 0 C default at 25 0 C Temperature Coefficient 0 0 to 4 0 default at...

Page 20: ...odel and serial number handy including data regarding the reason for return For your protection items must be carefully packed to prevent damage in shipment and insured against possible damage or loss...

Reviews: