background image

                             

                                                                                      WE ARE HERE TO SURPRISE! 

 

         

 

1.4 Notice of environment and condition. 
 

In general, this auto lift to be installed on the following terms:

 

1.4.1 Supply voltage: 0.9-1.1 nominal supply voltage. 

1.4.2 Source frequency: 0.99 to 1.01 nominal frequency. 

1.4.3 Ambient temperature: 5 ° C - 40 ° C 

1.4.4 Height: must be at altitudes of up to 1000 m above sea level. 

1.4.5 Humidity: Not to exceed 50% at 40 ° C 

1.4.6 Atmosphere: Free from dust, acid fumes, corrosive gases and salt. 

1.4.7 Avoid exposure to direct sunlight or heat rays that can alter the environmental temp. 

1.4.8 Avoid exposure to abnormal vibrations. 

1.4.9 Electrical equipment must withstand the effects of transport and storage temperature within a range 

of -10 ° C to 55 ° C and for short periods of max. +60 ° C - no more than 24 hours. 

 
1.5 Warning signs. 

All safety warning signs attached on the machine are for the purpose of 

drawing the user’s attention to safety operation. The 

labels must be kept clean and need to be replaced when they are worn-out or fallen off. Read the explanations of the labels 

carefully and try to memorize them.   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for Euroline JA3000S-E

Page 1: ...roline Mid rise service scissorlift Installation operation and maintenance manual Read this entire manual carefully and completely before installation or operation of the lift Reservations are made for printing writing and spelling errors in this manual Original ...

Page 2: ...ing 3 1 3 Ground conditions 3 2 Precautions for installation 4 Installation instructions 8 10 4 1 Installation instructions 4 2 Items to be checked after installation 5 Adjustment check and operationtest 10 5 1 Adjustments add oil and check the order of phases 5 2 Drainage adjustment 5 3 Operating test 5 4 Lowering safety In case of being embedded 6 To be checked after installation 11 7 Operating ...

Page 3: ...e lift on an asphalt surface 1 3 2 Read and understand all safety warnings before operating the lift 1 3 3 Outdoor sandblasting undercoating and other environments that differ from general immortal auto mechanic tasks 1 3 4 Keep hands and feet away from any moving parts Keep feet clear of the lift when lowering 1 3 5 Only qualified people who have been properly trained can operate the lift 1 3 6 D...

Page 4: ...e gases and salt 1 4 7 Avoid exposure to direct sunlight or heat rays that can alter the environmental temp 1 4 8 Avoid exposure to abnormal vibrations 1 4 9 Electrical equipment must withstand the effects of transport and storage temperature within a range of 10 C to 55 C and for short periods of max 60 C no more than 24 hours 1 5 Warning signs All safety warning signs attached on the machine are...

Page 5: ...ower cord wire to a live terminal This is for ground only 13 DANGER The power unit used on this lift contains high voltage Disconnect power at the receptacle before performing any electrical repairs Secure plug so that it cannot be accidentally plugged in during service 14 WARNING RISK OF EXPLOSION This equipment has internal arcing or sparking parts which should not be exposed to flammable vapour...

Page 6: ...ns one with anti surge valve in hydraulic system to prevent sudden drop down of platform in case the oil hose brake Without power you must open the control cabinet and turn the lowering valve manually so lift vehicle goes back down 2 2 Technical data Model Lifting capacity Lifting time Lifting height Height Total width Platform length Power supply Noise Weight JA3000S E 3000KG 45 Sec 960mm 105mm 1...

Page 7: ...se any parts missed but if you do not contact us and insist installing upon the lack of some parts Jema Autolifte A S as well as our dealers will not bear any responsibility for this and will charge for any parts subsequently demanded by the buyer 3 1 3 Ground conditions The lift should be fixed on a smooth and solid concrete ground with its strength more than 3000psi tolerance of flatness less th...

Page 8: ...t should be placed But within the length of the oil hose reach Step 3 1 Drill holes in the floor to the Expansion bolts with a drillhammer Be sure that the holes are drilled vertically into the concrete floor 2 After the holes are drilled see picture 1 remove dirt and dust from drilling the holes Make sure that the columns are where drawn with chalk 3 Expansion bolts knocked down N B Do not tighte...

Page 9: ...ISE 9 T 2 Step 4 Oilhose installation Install the oilhose according to the oilhose diagram which is shown in the manual It s important to make sure that all connections are cleaned and tensioned so there is no oil leakages ...

Page 10: ... been made properly If the lift does not go up the three phasesin the main supply connection should be interchanged The main switch should be previously disconnected 5 2 Drainage adjustment Switch on the lift and check that the oil tank is full Press the UP button The first time the cylinders may perform jerking movements which is normal and due to air in the circuit Continue the lifting until the...

Page 11: ...ed correctly 5 Is the rest of the joints tightened correctly 6 Are all places that need lubrication lubricated 7 Operating instructions Before entering a car on the lift make sure that the platforms are at it s lowest position When placing a car on the lift the weight must be as centered as possible Read operating and safety manuals before using the lift Load vehicle onto the lift using the vehicl...

Page 12: ...activated but it does not work Check the plug and spool of the drop valve check the correct nut seal Should it be replaced The Parachute Valve is blocked Remove the parachute valve from the oil supply hole at the bottom of the cylinder and clean the device The lift lowers very slowly when subjected to weight loads in the standard range Hydraulic oil has a high viscosity is deteriorated or frozen i...

Page 13: ...orks optimal and safe The following are requirements for normal maintenance You can choose the frequency of routine maintenance according to the daily load on the lift If the user carefully follows the above requirements for maintenance lift kept in good condition and accidents will largely be avoided ...

Page 14: ...WE ARE HERE TO SURPRISE 14 Annex 1 Overview Pictures ...

Page 15: ...WE ARE HERE TO SURPRISE 15 Annex 2 Hydraulic diagram ...

Page 16: ...WE ARE HERE TO SURPRISE 16 Annex 3 Lift exploded drawing ...

Page 17: ...WE ARE HERE TO SURPRISE 17 12 11 10 9 8 8 2 1 3 4 5 6 5 7 13 Annex 4 CYLINDER EXPLOSED VIEW ...

Page 18: ...WE ARE HERE TO SURPRISE 18 Annex 5 380V electric wire diagram ...

Page 19: ...CE Machine Directive 2006 95 CE Low Voltage Equipment and Harmonized Standards and technical specifications used in where applicable EN 1493 2011 VehicleLifts EN 12100 2012 Safety of machinery General principles for design Risk assessment and risk reduction EN 60204 1 2007 Safety of machinery Electrical equipment of machines General requirements xxxxxxxxxxxxxxxxxxxx certifies that this machine has...

Page 20: ...WE ARE HERE TO SURPRISE 20 Industrihegnet 2 4030 Tune Denmark Website www jemaautolifte dk Mail info jemaautolifte dk Phone No 45 48180300 Jema Autolifte We are here to surprise ...

Reviews: