HEAVY FOG GLACIATOR

USER
GUIDE

12

BASIC OPERATION

The following instructions explain how to operate the basic functions of the
machine. It is assumed that the machine is being started from cold.

Starting with all the control panel switches OFF, and the display showing
‘OFF’, go through the following sequence.

Set the Standby switch to ON.

Fog display shows FOG/Ht
Ice display shows Den/nor

Set the output to Fog = 8

Set the Ice switch to ON

When the machine is ready (after approx. 20 minutes heat-up time) fog can
be produced.

Fog display shows FOG/Rdy

If starting the machine for the first time, or after the fluid has been changed,
the pump may need to be primed.
Do this by setting the Fog output to 15 and firing the machine for 10
seconds, or until fog is produced at the output.
If the pumps have not primed after 20 seconds, there may be a problem with
the fluid system. Refer to the Fault Finding section of the handbook for
advice.

Set the Fog switch to ON to produce continuous output of Heavy Fog.

Fog display shows FOG/08
Ice display shows Den/nor

Set the Timer switch to ON to produce timed output (read the Timer section
to see how to configure the timer). Note that the Fog switch overrides the
timer switch.

Fog display shows ton/04,toff/03 etc

Ice display shows Den/nor

Ice display shows Den/nor

COMMISSIONING THE MACHINE

HEAVY FOG GLACIATOR

USER
GUIDE

5

Unpack the machine and look for any obvious signs of damage.

Place the machine on a level surface and fit a container of JEM/Martin
approved fluid into the fluid compartment. Fit the fluid line and cap to the
container.

Check the wiring instructions in the Safety Guidelines section of this
handbook and connect the machine to the power supply.

Set the power switch in the power inlet box to the ON position, and look for
the start-up message on the displays.

Set all the switches on the control panel to OFF and refer to the Basic
Operation section of this handbook for information on how to use the main
functions of the machine. Read the

before using the

machine.

Safety Guidelines

REMOTE CONTROL OPTIONS

The Heavy Fog Glaciator provides the user with 3 ways to implement a
remote control on the machine. The main control panel is fixed and can not
be removed for remote operation.
All the remote interfaces are located on the panel adjacent to the control
panel.
The options are:

.

The interface uses the two XLR 3 connectors marked DMX on the interface
panel, and uses the usual DMX electrical standards (RS 485). The inputs
are protected against overvoltage and an ouput connector is provided to
allow multidrop operation of the link.

.

The remote interface uses an XLR 3 connector to allow a standard JEM
remote to fire the machine.
Full proportional control of the Fog output can be achieved, but the Density
level must be set on the control panel.

.

This connection is an option available to installers who wish to control the
machine using the ouputs from a standard Programable Logic Controller
(PLC). When the interface PCB is fitted, 12/24v DC control signals can be
used to switch the Fog, Standby, Timer and Ice functions. The output levels
and timer settings must be made using the control panel.

DMX 512 Digital Interface

Remote Interface

PLC Interface

Summary of Contents for HEAVY FOG GLACIATOR

Page 1: ...Unit C6 Hastingwood Trading Estate 35 Harbet Road London N18 3HU Phone 020 8803 7400 FAX 020 8803 5060 email office gradav co uk ...

Page 2: ...1 GND 2 COLD 3 HOT FUSE RATINGS The Heavy Fog Glaciator uses four fuses They should be replaced with the value and type detailed below DMX receiver low voltage 2AT Power PCB 12AT Compressor control relay 12AT Main input fuse 20AT Three of these fuses are located internally and should not be accessed without first disconnecting the power supply FILTERS The Heavy Fog Glaciator uses a washable synthe...

Page 3: ...0 seconds 90 seconds REFRIGERATION UNIT 2 3 HP compressor with thermostatic control Uses refrigerant R404A 0 850 Kg OUTPUT CONNECTION Ducting adaptor to accept 150mm 6 flexible ducting POWER REQUIREMENTS Input voltage 200 250vac Input power max 3 1Kw Main fuse 20AT Frequency 50 60Hz dependant on model Maximum fluid consumption 120mL minute REMOTE CONTROL OPTIONS HEAVY FOG GLACIATOR USER GUIDE 16 H...

Page 4: ...ptional PLC interface Non volatile memory for user settings Electronic low fluid detection High pressure piston pump LED displays for FOG and ICE controls Fog and Density controls for easy set up Accurate timer Remote interface USER GUIDE HEAVY FOG GLACIATOR 2 HEAVY FOG GLACIATOR USER GUIDE 15 Fan Display Displayed when the Standby switch is set to OFF Shows the current Density setting Compressor ...

Page 5: ...oltage is correct for use with the machine the voltage setting is printed on the serial label The machine must be operated in a horizontal position and should not be suspended overhead Observe the warnings displayed on the machine yellow labels Do not remove the covers or attempt to repair a faulty machine an autho rized JEM dealer should be contacted in the event of a faulty machine Always use sm...

Page 6: ...ut of fluid This is overcome in the Heavy Fog Glaciator by using an electronic fluid sensing system ensuring that the pump is shut down when the fluid level is too low The Left hand display will show a Lo Flu message to warn the user that the machine is shut down due to lack of fluid Variations in pump performance due to supply frequency differences 50 60Hz are compensated for automatically Supply...

Page 7: ...id into the fluid compartment Fit the fluid line and cap to the container Check the wiring instructions in the Safety Guidelines section of this handbook and connect the machine to the power supply Set the power switch in the power inlet box to the ON position and look for the start up message on the displays Set all the switches on the control panel to OFF and refer to the Basic Operation section...

Page 8: ...g set into the switches HEAVY FOG GLACIATOR USER GUIDE 6 HEAVY FOG GLACIATOR USER GUIDE 11 ICE Setting this switch to ON will start the compressor displays St while starting If the compressor fails to start within 10 seconds the display will show StL and the compressor will be shut down This function is independent of the status of the STANDBY switch THE TIMER The timer system is implemented in so...

Page 9: ...ed The standby switch brings the machine into operating mode and will start the heater This switch must be ON to use the Fog switch or the Timer When Standby is OFF the machine will display OFF on both displays With standby ON and the machine ready Rdy will be on the Fog display When the machine is Ready at operating temperature the timer switch will start the timer running using the settings from...

Page 10: ...Y DOWN KEY ENTER KEY MENU KEY HEAVY FOG GLACIATOR USER GUIDE 9 To store the new value into non volaile memory the enter key must be pressed before moving on to another menu or leaving the edit mode When not in edit mode the display will show information appropriate to the current operating mode To do this the display will alternate between two messages The duration of the first message is typicall...

Reviews: