24
Glaciator X-Stream user manual
will then repeat itself until the Timer switch is set to OFF. Switching the
Timer to OFF at any time during the cycle will halt the operation.
The Timer will only function when the Standby switch is set to ON and the
machine is ready (RdY). The Timer can be switched on when powering up
the machine, though this will cause the timer to start running, and smoke
being fired, as soon as the machine is showing ‘RdY’ on the display (after
approximately 5 minutes). At this point the smoke may not come out as a
low fog since the evaporator coils may not yet have been cooled down.
The timer function is controlled by the machine's main control PCB, which
make it more accurate than the usual analogue timers commonly found on
fog machines.
M E S S A G E S
F o g D i s p l a y
Fog/oFF
Displayed when the Standby switch is set to OFF,
indicating that the machine can not be fired and the
heaters are OFF.
Fog/Err
Shows that the Standby switch is ON but the heater is
not on. This is an error condition and should not
normally occur.
Fog/Ht
Displayed when the heater is running but the machine is
not ready.
Fog/rdy
The machine is ready to fire using the Fog or Timer
switches.
Fog/08
The FOG switch is being used to fire the machine. The
number displayed is the current Fog output level in the
range 0 to 20
FLu/Lo
Indicates that the fluid in the container is below the
minimum level to operate the machine. Only visible
when the machine has reached its ready state.
ton/04 - toF/03
The Timer switch is being used. The numbers displayed
are the current Timer ON-period and OFF-period in
seconds.