Jegs 88500 Owner'S Manual Download Page 5

 

 

5.2 USING THE USB PORT  

 

The USB port provides up to 2.4A at 5V DC.  
1.  Ensure the battery clamps are securely clipped on the storage holders.  
2.  Flip the ON/OFF power switch to turn the unit ON.  
3.  Plug your device into the USB port.  
4.  Turn on the USB device.  
5.  When finished using the USB port, flip the switch to the OFF position.  
6.  Recharge the unit as soon as possible after each use.  
 

5.3 USING THE WORK LIGHT  

 

1.   Position the jump starter on a flat, stable surface near the intended work area.  

2.   Ensure the battery clamps are securely clipped on the storage holders.  

3.   Flip the ON/OFF power switch to the ON position.  

4.  Press the Battery Status/Light button on the front of the unit for 0.75 second, to turn on the work light.  

5.   When finished using the work light, press the button for 0.75 second, to turn off the work light.  

6.   Recharge the unit as soon as possible after each use.  
 

 

 

5.4 USING THE AIR COMPRESSOR 

 

 

WARNING

 Read the instructions of the product being inflated before using the compressor. Avoid over inflation; do 

not exceed the manufacturer’s recommended pressures. Do not leave the air compressor unattended during use.  

1.  Remove the air compressor hose from the storage cleats.  
2.  Connect the adapter to the valve stem by threading it onto the end. If necessary, use one of the additional 

adapters.  

3.  Turn ON the compressor power switch and inflate to the desired pressure or fullness.  

NOTE

: To prevent overheating, the compressor has built-in thermal protection that will turn the compressor off before it 

overheats. If the compressor shuts off, wait a few minutes and it will automatically restart when the compressor cools.  
4.  When the desired pressure is reached, move the compressor power switch to OFF and unthread the connector   
     from the valve stem.  
5.  Wrap the compressor hose around these cleats when it is not being used.  

ESTIMATED TIME FOR INFLATING 

Vehicle tires 13-16" 

6-24 minutes 

Bike tires 

1-3 minutes 

Sports balls 

30 seconds 

6.  Allow unit to cool.  
7.  Recharge the unit before storing.  

NOTE

: The air compressor is rated for 150 PSI.  

 

 

5.5 ENERGY SAVING MODE 

If the unit is not used after the ON/OFF power switch is turned on, the unit will go into Energy Saving mode after 10 
minutes to prevent battery discharge. Follow these steps to use any function after Energy Saving mode: 

1. Press the ON/OFF power switch to turn the unit ON. 

2. The Green Ready/Fail LED will light. 

3. After 10 minutes, The USB port and Battery Status/Light function will turn off. 

4. After 10 minutes, The Green Ready/Fail LED will turn off. 

5. Press the Battery Status/Light button once. The unit is now ready for checking the battery status and using the jump 
starter, compressor, USB and work light.  

 

 

 

 

                                         1-800-345-4545   jegs.com

 

Summary of Contents for 88500

Page 1: ... 1 5 The jump starter gets hot during charging and must have proper ventilation 1 6 Do not set the jump starter on flammable materials such as carpeting upholstery paper cardboard etc 1 7 Place the jump starter as far away from the battery being jumped as the cables will permit 1 8 Do not expose the jump starter to rain or snow 1 9 Never attempt to jump start a frozen battery 1 10 Never place the ...

Page 2: ...h water an aqueous based extinguishing agent or other nonalcoholic liquids to cool the product and prevent the battery from re igniting NEVER attempt to pick up or move a hot smoking or burning product as you may be injured 2 8 NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provi...

Page 3: ...eady Fail LED 10 Air compressor gauge 4 Battery status Light button 11 Air compressor hose wrap cleats 5 Battery status indicators 12 Air compressor hose 6 Built in work light 13 Air compressor adapters and storage bag 7 ON OFF Power switch 14 Micro USB charging cable 1 800 345 4545 jegs com 7 9 10 8 11 12 14 13 ...

Page 4: ...tion has been activated such as short circuit protection battery low voltage protection reverse polarity protection etc and the unit will not operate 6 When the battery is fully charged disconnect your charger from the power source and then remove the charging cable from the charger and the unit Make sure the power switch is set to OFF if not using the jump starter immediately 5 OPERATING INSTRUCT...

Page 5: ... end If necessary use one of the additional adapters 3 Turn ON the compressor power switch and inflate to the desired pressure or fullness NOTE To prevent overheating the compressor has built in thermal protection that will turn the compressor off before it overheats If the compressor shuts off wait a few minutes and it will automatically restart when the compressor cools 4 When the desired pressu...

Page 6: ...front of the unit The LEDs will indicate the status of charge Have the battery checked Press ON OFF switch to turn on the jump starter The jump starter will not operate Low temperature protection Use the USB adaptor to charge and activate The battery in the jump starter won t hold a charge The battery is bad will not accept a charge Have the battery checked The compressor shuts off The compressor ...

Page 7: ... if the product is misused subjected to careless handling repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied or statutory warranties including without limitation any implied warranty of merchantability or implied warranty of fitness for a particular pur...