Note:
Consumers must be careful to not overtighten the air/gas fitting on the Cut 40 gas receptacle located on the back of the
unit when connecting the unit to air/gas.
Over tightening will possibly shift the air/water separator inside the unit. Shifting of the air/water separator may cause
the relief valve on the air/water separator to be depressed resulting in failure to pressurize and the sound of leaking air
when trying to pressurize. If the air/water separator has shifted and the system will not pressurize the problem is easily
corrected by re-centering the air/water separator relief valve in relation to the vent hole located on the bottom of the unit
by un torqueing the gas receptacle on the back of the unit to its original location allowing the air/water separator to be
centered in its relief hole on the bottom of the unit.