Installment 

 

This machine is equipped with voltage compensation hardware. When power voltage varies within ± 15% of 
rated voltage, it can still work normally. 
 
When using a long power cable, to prevent voltage drop, a larger section cable is suggested. Failure to do so 
may affect the performance of the power system.  We suggest using the shortest length possible. 

1.  Make sure intake of the machine is not blocked or covered, lest cooling system could not work. 
2.  Make good connection with shielded gas source. Gas supply includes cylinder, argon decompress flow 

meter and pipe. Be sure all piping connections are secure and check for leaks. 

3.  Use inducting cable whose section is not less than 

¼” to connect the housing to the ground. The way is 

from the ground connecting screw at the back to the ground device. 

4.  Correctly connect the arc torch or holder according to the sketch. When using MMA welding; be sure 

the cable, holder and fastening plug have been 
connected with the ground. Put the fastening 
plug into the fastening socket at the “ - “ 
negative polarity and fasten it clockwise. When 
using arc welding: put the gas-electricity plug of 
the welding gun to the joint at the front panel, 
and fasten clockwise. Put the air switch on the 
gun to the relevant joint at the front panel, and 
fasten the screw.  

5.  Put the fastening plug of the cable to the 

f

astening socket of “ + ” positive polarity at the 

front panel, fasten it clockwise, and the ground 
clamp at the other terminal clamps the work 
piece. 

6.  According to input voltage grade, connect power 

cable with power supply box of relevant voltage 
grade. Make sure the voltage difference is 
among permission range. After the above installment is finished welding is available. 
 

Warning! Before connecting operation please make sure all the power is turned off. First, connect the welding 
cable and ground cable to the machine, make sure they are firmly connected and then put the power plug to 
the power source. 
 
Panel Instruction 
 

The panel picture is for reference only. If any difference with the real machine, please follow with the real 
machine.

  

 

 

                                         1-800-345-4545   jegs.com

 

Summary of Contents for 81542

Page 1: ... Keep your head out of the gas When you are welding air extractor should be used to prevent inhalation of gas Arc radiation Harmful to eyes and burns the skin Use suitable helmet and light filter wear protective garments to protect eyes and body Use suitable helmet or curtain to protect bystander Fire Welding sparks may cause risk of fire make sure the welding area has no tinder around Noise extre...

Page 2: ...lding power source can offer a stronger more concentrated and stable arc When stick and work piece get short the response time will be quicker Can even be adjusted to make arc softer or harder This machine can be used for multiple materials such as stainless steel carbon steel copper and other color metals Can also be used for traditional electric welding Its transfer efficiency is above 85 CAUTIO...

Page 3: ...een connected with the ground Put the fastening plug into the fastening socket at the negative polarity and fasten it clockwise When using arc welding put the gas electricity plug of the welding gun to the joint at the front panel and fasten clockwise Put the air switch on the gun to the relevant joint at the front panel and fasten the screw 5 Put the fastening plug of the cable to the fastening s...

Page 4: ...atening and cause severe damage to the machine Preventive Measures 1 Environment The machine can perform in an environment where conditions are dry with maximum humidity level of 90 Ambient temperature is between 50 F to 104 F 10ºC to 40ºC Avoid welding in the rain Do not use the machine in an environment where conditions are polluted with conductive dust or corrosive gases Avoid gas welding in th...

Page 5: ...arc and cause unstable arc C Output current not to rated value When power voltage departs from the rated value it will make the output current differ with the rated value When voltage is lower than rated value the max output may be lower than rated value D Current is not stabilizing when machine is being operated 1 Electric wire net voltage has been changed 2 There is harmful interference from ele...

Page 6: ...ghten it again 2 Arc striking tip is oxidized or too far give a good polish to it or change it about 0 04 1mm between arc striking tip 3 Switch sticking argon arc welding is damaged replace it 4 Some of HF arc striking circuit components are damaged find out and replace Abnormal indicator is lit but there is no welding output 1 Overheat protection close machine first then open again after abnormal...