USER MANUAL

 

6.9kVA Petrol Generator 

JEFGENPET55EL

www.jeffersontools.com

9. Maintenance

Daily

20 Hours Usage

50 Hours Usage

100 Hours Usage

300 Hours Usage

Engine oil check

Replace engine oil 

Check air cleaner

Wash the air cleaner

Oil filter cup

Oil filter

Spark plug

Valve clearance 

 

Clean cylinder cover wash

Fuel tank wash

Wash regularly replace every three years

Check the battery and  
electrolyte levels

Before use

The chart below indicates the maintenance checks you should make on your generator parts and the frequency that 
these checks should generally be carried out. 

Note:

 You can contact your nearest Jefferson dealer for help and  

advice and a full list of replacement parts. 

Check 

Frequency 

Notes: 

• 

Checking and the engine oil: 

With generator on level ground: remove the oil filler cap and dipstick clean with a    

   clean cloth. Insert the dipstick back into the oil filter hole without turning - remove and check that the oil level is    
   between the minimum and maximum indicators. If level is low refill to the maximum level mark. 

 Checking the fuel level:

 With generator on level ground: open the fuel tank cap. Check the fuel level. If level is low   

   refuel up to the red marker on the fuel filter. Put the fuel cap back on.

WARNING:

• Ensure that any electrical equipment is disconnected from the generator before carrying  

   out any maintenance work on the generator.  

 

• The circuit breaker should be in the "OFF" position before maintenance.

• The unit should be eatherd at all times.

 

 

 

Summary of Contents for OLYMPUS JEFGENPET55EL

Page 1: ...OLYMPUS OLYMPUS User Manual v 1 1 6 9kVA Key Start With Electronic Ignition AVR JEFGENPET55EL...

Page 2: ...rator 7 Stopping the Generator 8 Transportation and Storage 9 Operation Environment 10 Maintenance 11 Troubleshooting 12 Parts List Diagram 13 Circuit Diagram Limited Warranty Statement EC Declaration...

Page 3: ...nt electric shock or fire never use the machine in rain or snow or connect the generator to a live circuit 12 Do not connect the generator to another power supply outlet 13 Protection against electric...

Page 4: ...unit or refuelling an empty tank You can drain away air by loosening the connection between the injection pump and pipeline then drain the air until the fuel comes out Do not loosen or adjust either t...

Page 5: ...erious burns or fires Let the engine cool before transporting or storing the generator Make sure not to drop or strike the generator when transporting Do not place heavy objects on top of the generato...

Page 6: ...help and advice and a full list of replacement parts Check Frequency Notes Checking and the engine oil With generator on level ground remove the oil filler cap and dipstick clean with a clean cloth I...

Page 7: ...hnical Specification Noise Level Information The figures quoted in this table are emission sound power levels and are not necessarily safe working levels Whilst there is a correlation between the emis...

Page 8: ...lay bracket 1 35 029930000801 grounding wire 1 36 029050601383 Left handle bracket 1 37 029050600101 Pressure button spring 2 38 029050601583 handle 2 39 029050601483 Right handle bracket 1 40 0290504...

Page 9: ...9 USER MANUAL 6 9kVA Petrol Generator JEFGENPET55EL www jeffersontools com...

Page 10: ...10 USER MANUAL 6 9kVA Petrol Generator JEFGENPET55EL www jeffersontools com 13 Circuit Diagram 1 PH Socket 110V 32A 1 PH Socket 230V 16A...

Page 11: ...he repair or replacement of warranty covered equipment will be subject to a minimum of 90 days cover or the remaining duration of the warranty period from the original date of purchase Warranty Regist...

Page 12: ...he form online and submit it to us directly or download the form to print out and return by post Telephone Method Contact your Jefferson dealer or sales representative with the following information M...

Page 13: ...y Where parts are not immediately available Jefferson will contact you with a revised date for completion of the repair General Warranty Enquiries For any further information relating to Jefferson war...

Page 14: ...50 6 9kVA 5 5kW Petrol Generator Rated Power 6 3kVA 5 0kW The conformity assessment procedure followed was in accordance with Annex VI of the Outdoor Noise Directive Notified Body SNCH Luxembourg GmbH...

Page 15: ...15 USER MANUAL 6 9kVA Petrol Generator JEFGENPET55EL www jeffersontools com 14 Notes...

Page 16: ...rk Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating...

Reviews: