background image

14

USER MANUAL

 

6.9kVA Petrol Generator 

JEFGENPET55EL

www.jeffersontools.com

EC Declaration of Conformity

We, Jefferson Professional Tools & Equipment, as the authorised European  

Community representative of the manufacturer, declare that the following equipment  

conforms to the requirements of the following Directives: 

 

2000/14/EC (as amended)  

Noise Emission in the Environment by Equipment  

     for 

Use 

Outdoors

 

2004/108/EC (as amended) 

Electromagnetic Compatibility 

 

2006/42/EC (as amended) 

Machinery Directive

 

 

97/68/EC (as amended) 

Non Road Mobile Machinery Directive

Equipment Category:    

Power Generator (Item 45) 

Product Name/Model:   

JEFGENPET55EL (GG6150) 6.9kVA / 5.5kW Petrol Generator   

    

Rated Power:

  6.3kVA / 5.0kW

The conformity assessment procedure followed was in accordance with Annex VI of the Outdoor Noise Directive

Notified Body:

   

 

 

SNCH Luxembourg GmbH. (No. 0499)

Measured Sound Power Level:

 97dB

Guaranteed Sound Power Level:

 97dB

A copy of this certificate has been submitted to the European Commission and to the  

EU Member State, 

United Kingdom

Signed 

by: 

   

Stephen McIntyre 

  

Position in the company:   

 

Operations Director

Date: 

   

 

 

 

29 September 2014 

This technical document is held by:

  Jimmy Hemphill

     

Technical file holder's address as shown below

Name and address of manufacturer or authorised representative: 

 

Jefferson Tools, Herons Way, Chester Business Park, Chester, United Kingdom, CH4 9QR

Telephone:

 +44 (0)1244 646 048  

Fax: 

+44 (0)1244 241 191 

Email:

 [email protected]

www.jeffersontools.com

 

Summary of Contents for OLYMPUS JEFGENPET55EL

Page 1: ...OLYMPUS OLYMPUS User Manual v 1 1 6 9kVA Key Start With Electronic Ignition AVR JEFGENPET55EL...

Page 2: ...rator 7 Stopping the Generator 8 Transportation and Storage 9 Operation Environment 10 Maintenance 11 Troubleshooting 12 Parts List Diagram 13 Circuit Diagram Limited Warranty Statement EC Declaration...

Page 3: ...nt electric shock or fire never use the machine in rain or snow or connect the generator to a live circuit 12 Do not connect the generator to another power supply outlet 13 Protection against electric...

Page 4: ...unit or refuelling an empty tank You can drain away air by loosening the connection between the injection pump and pipeline then drain the air until the fuel comes out Do not loosen or adjust either t...

Page 5: ...erious burns or fires Let the engine cool before transporting or storing the generator Make sure not to drop or strike the generator when transporting Do not place heavy objects on top of the generato...

Page 6: ...help and advice and a full list of replacement parts Check Frequency Notes Checking and the engine oil With generator on level ground remove the oil filler cap and dipstick clean with a clean cloth I...

Page 7: ...hnical Specification Noise Level Information The figures quoted in this table are emission sound power levels and are not necessarily safe working levels Whilst there is a correlation between the emis...

Page 8: ...lay bracket 1 35 029930000801 grounding wire 1 36 029050601383 Left handle bracket 1 37 029050600101 Pressure button spring 2 38 029050601583 handle 2 39 029050601483 Right handle bracket 1 40 0290504...

Page 9: ...9 USER MANUAL 6 9kVA Petrol Generator JEFGENPET55EL www jeffersontools com...

Page 10: ...10 USER MANUAL 6 9kVA Petrol Generator JEFGENPET55EL www jeffersontools com 13 Circuit Diagram 1 PH Socket 110V 32A 1 PH Socket 230V 16A...

Page 11: ...he repair or replacement of warranty covered equipment will be subject to a minimum of 90 days cover or the remaining duration of the warranty period from the original date of purchase Warranty Regist...

Page 12: ...he form online and submit it to us directly or download the form to print out and return by post Telephone Method Contact your Jefferson dealer or sales representative with the following information M...

Page 13: ...y Where parts are not immediately available Jefferson will contact you with a revised date for completion of the repair General Warranty Enquiries For any further information relating to Jefferson war...

Page 14: ...50 6 9kVA 5 5kW Petrol Generator Rated Power 6 3kVA 5 0kW The conformity assessment procedure followed was in accordance with Annex VI of the Outdoor Noise Directive Notified Body SNCH Luxembourg GmbH...

Page 15: ...15 USER MANUAL 6 9kVA Petrol Generator JEFGENPET55EL www jeffersontools com 14 Notes...

Page 16: ...rk Chester United Kingdom CH4 9QR Tel 44 0 1244 646 048 Email sales jeffersontools com IMPORTANT SAFETY FIRST Before attempting to use this product please read all the safety precautions and operating...

Reviews: