GETTING TO KNOW YOUR VEHICLE
17
ON
ON
ON (2 Blinks)
Lack of grounding cable in the charging
socket of the domestic power supply mains.
The new charge attempt failed. Disconnect
the charge cable from the vehicle and the
outlet and reconnect it, then try to charge
again.
Contact a certified electrician in case of a
new anomaly.
ON (Flashing)
OFF
OFF
Domestic mains power incorrectly supplied.
The system will make a new charge attempt
after 30 seconds (6 attempts total).
If the fault persists, disconnect the charge
cable from the vehicle and the outlet and
reconnect it, then try to charge again.
Contact a certified electrician in case of a
new anomaly.
ON
ON (Flashing)
OFF
Charge Current Interrupt Device (CCID) fault
trip over one second after relay closure.
Cordset retrying to charge the vehicle.
The system will make a new charge attempt
after 30 seconds (6 attempts in total).
ON
ON
OFF
Charge Current Interrupt Device (CCID) fault,
Retry Exhausted or Retry is disallowed if
trips within one second of relay closure.
The new charge attempt failed. Disconnect
the charge cable from the vehicle and the
outlet and reconnect it, then try to charge
again.
Contact an authorized dealer in case of a
new anomaly.
Portable Charging Cordset (EVSE) Charging System Failure
Green LED
Red LED
Yellow LED
Description
Action/Consequences
2