TECHNICAL

DC POWER

6

AC POWER

SWITCHED 1~6 : 230VAC / 7000VA(30A)

                            : 120VAC / 3600VA(30A)

Power Consumption

120W(DC Power 24V / 3A

부하)

24V/1.5AMAX x 2

SWITCHED 7~9 : Each max 115VA

UNSWITCHED   : 360VA max

Specifications and design subject to change without notice for improvements.

(내용상의 규격 및 특징은 제품의 성능 향상을 위하여 사전 예고 없이 변경될 수 있습니다.)

GENERAL

NOTE

Power(option)

AC 120V/220V/230V/240V 50~60Hz

Dimensions

Weight

8Kg / 17.6Ibs

483(W) x 133(H) x  350(D)mm
  19(W) x  5.2(H) x 13.8(D)inch

Condition detection

1 Mode (POWER CHECK)

Summary of Contents for JPD-322AU

Page 1: ...WWW JEDIA COM POWER DISTRIBUTOR JPD 322AU...

Page 2: ...6 3 4 5 2 POWER AC REMOTE POWER DISTRIBUTOR JPD 322AU 1 UN SWITCHED AC FUSE MAIN SWITCHED 2 3 4 5 6 7 8 9 CAUTION TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE...

Page 3: ...e a fire or selection for remote microphone from Remote Amplifier AC power of distributor will be turn ON for supplying AC power to the rack system 5 Built in protection against 24VDC output terminal...

Page 4: ...hough power switch of power distributor is OFF when pushing talk switch of JRA 051A power will be ON to supply rack system 3 When pushing E M speaker selector switch or emergency situation like a fire...

Page 5: ...TCHED AC OUTLET 1 6 Push the switch to the upper to supply AC power It should be used only for power supply of power amplifier IMPORTANT NOTICE Built in power delay circut for 1 6AC outlet to reduce A...

Page 6: ...gency situation automatic power remote control IMPORTANT NOTICE Be sure not to change polarity REAR PANEL CONTROLS 9 8 TO OTHER JPD 322A JCU 160 JCU 160 JCU 160 CHECK SIGNAL CHECK SIGNAL JCU 160 E M R...

Page 7: ...AC 230V 50Hz 1420W MODEL JPA 1 CHANNEL P A POWER AMPLIFIER MADE IN KOREA CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DON T EXPOSE THIS EQUIPMENT TO...

Page 8: ...24V 3A 24V 1 5AMAX x 2 SWITCHED 7 9 Each max 115VA UNSWITCHED 360VA max Specifications and design subject to change without notice for improvements GENERAL NOTE Power option AC 120V 220V 230V 240V 50...

Page 9: ...00VA EACH MAX 3500VA 115VA 115VA 115VA REMOTE E M R M CONTROL AC PWR DETECTOR DC 24V EQUIPMENT ONLY 2 3Sec GND AC POWER 50 60Hz 120V 220V 230V 240V OPTION POWER TRANS 360VA MAX UNSWITCHED SWITCHED 1 S...

Page 10: ...EMO M...

Page 11: ...JPD 322AU OPERATING INSTRUCTIONS 4M OP207110 080105 POWER DISTRIBUTOR...

Reviews: