background image

1. FUSE COVER

3. POWER SWITCH

2

Push the power switch to operate rack system.

1. FUSE COVER

Unscrew 4pcs bolt and remove blown fuse.

4. AC, REMOTE LED

2. FUSES

There are three of fuse No.1~9 fuse are switched power out, fuse for

unswitched power output and fuse power distributor.

AC LED

Turn in the power switch No.3 to make a lighting.

휴즈를 교환시 4개의 볼트를 드라이버로 풀고 휴즈 덮개를 제거하면
내장된 휴즈가 보입니다.

4. AC, REMOTE LED

3. POWER SWITCH

위로 스위치를 누르면 파워 디스트리뷰터의 모든 기능이 동작됩니다.

2. FUSE

휴즈는 연동출력1 9와 비연동출력 그리고 파워 디스트리뷰터 보호
용 휴즈로 구분되어 있습니다.

IMPORTANT NOTICE : 

When thr fuse blown-out, it should be replaced with the same type

just like following table. 

If it continues to blow out, stop replacing fuse andrefer servicing 

to qualified person.

AC fuse

T2AH(55T), Unswitched

T3.15AH(55T), 

Switched

T15AL(65TL)

IMPORTANT NOTICE (POWER REMOTE CONTROL FUCTION) : 

1). When unexpected AC power failure, DC power from the battery

     (JEP-352U, JEP-352) will be supplied to the rack system auto

matically.

2). Even though, power switch of power distributor is "OFF", when

     pushing talk switch of JRA-051A, power will be "ON" to supply 

     rack system.

3). When pushing E/M speaker selector switch or emergency situation

     like a fire-out, power distributor will be "ON" automatically power 

     switch of power distributor.

중요사항 : 휴즈가 용단시 규격품을 사용하십시오.
AC FUSE→T2AH(55T), Unswitched→T3.15AH(55T),
Switched→T15AL(65TL)

중요사항(파워리모트 콘트롤 기능) :
1). 정전시 POWER DISTRIBUTOR(JPD-322AU,JPD-322A)의 POWER

SWITCH로 EMERGENCY POWER SUPPLY(JEP-352U,JEP-352)의
베터리 전압이 랙 시스템에 공급 되도록 콘트롤 됨.

2). POWER DISTRIBUTOR의 POWER SWITCH가 OFF되어 있어도

JRA-051A의 TALK(마이크동작) 스위치를 누르고 있는 동안,
POWER DISTRIBUTOR가 ON되어 랙 시스템에 전원이 공급됨.

3). POWER DISTRIBUTOR의 POWER SWITCH가 OFF되어 있어

도 EMERGENCY SPEAKER SELECTOR의 스피커 선택스위
치를 누르거나 긴급비상상태(화재발화)로 되면 POWER
DISTRIBUTOR가 ON되어 랙 시스템에 전원이 공급됨.

REMOTE LED

Remote LED is turn "ON" during the operation of remote 

amplifier or power remote control due to emergency situation 

or emergency speaker selector.

AC LED

3번의 파워 스위치를 ON하면 LED가 켜집니다.

REMOTE LED

REMOTE AMP 또는 EMERGENCY SPEAKER SELECTOR, 긴급 비
상상태(화재발화)로 파워 리모트 콘트롤시 LED가 켜집니다.

POWER

AC REMOTE

1

UN-

SWITCHED

AC FUSE

(MAIN)

2

3

4

5

6

7

8

9

SWITCHED

CAUTION:

 

TO REDUCE THE RISK OF

FIRE REPLACE ONLY WITH SAME TYPE FUSE.

1

2

3

4

POWER DISTRIBUTOR  

JPD-322AU

F

RONT PANEL CONTROLS 

(전면기능)

Summary of Contents for JPD-322AU

Page 1: ...WWW JEDIA COM POWER DISTRIBUTOR JPD 322AU...

Page 2: ...6 3 4 5 2 POWER AC REMOTE POWER DISTRIBUTOR JPD 322AU 1 UN SWITCHED AC FUSE MAIN SWITCHED 2 3 4 5 6 7 8 9 CAUTION TO REDUCE THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE FUSE...

Page 3: ...e a fire or selection for remote microphone from Remote Amplifier AC power of distributor will be turn ON for supplying AC power to the rack system 5 Built in protection against 24VDC output terminal...

Page 4: ...hough power switch of power distributor is OFF when pushing talk switch of JRA 051A power will be ON to supply rack system 3 When pushing E M speaker selector switch or emergency situation like a fire...

Page 5: ...TCHED AC OUTLET 1 6 Push the switch to the upper to supply AC power It should be used only for power supply of power amplifier IMPORTANT NOTICE Built in power delay circut for 1 6AC outlet to reduce A...

Page 6: ...gency situation automatic power remote control IMPORTANT NOTICE Be sure not to change polarity REAR PANEL CONTROLS 9 8 TO OTHER JPD 322A JCU 160 JCU 160 JCU 160 CHECK SIGNAL CHECK SIGNAL JCU 160 E M R...

Page 7: ...AC 230V 50Hz 1420W MODEL JPA 1 CHANNEL P A POWER AMPLIFIER MADE IN KOREA CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DON T EXPOSE THIS EQUIPMENT TO...

Page 8: ...24V 3A 24V 1 5AMAX x 2 SWITCHED 7 9 Each max 115VA UNSWITCHED 360VA max Specifications and design subject to change without notice for improvements GENERAL NOTE Power option AC 120V 220V 230V 240V 50...

Page 9: ...00VA EACH MAX 3500VA 115VA 115VA 115VA REMOTE E M R M CONTROL AC PWR DETECTOR DC 24V EQUIPMENT ONLY 2 3Sec GND AC POWER 50 60Hz 120V 220V 230V 240V OPTION POWER TRANS 360VA MAX UNSWITCHED SWITCHED 1 S...

Page 10: ...EMO M...

Page 11: ...JPD 322AU OPERATING INSTRUCTIONS 4M OP207110 080105 POWER DISTRIBUTOR...

Reviews: