background image

 

T470 Part A User’s Manual © Jed Micro Pty Ltd 

Page 2 

Step-through a typical setup sequence 

ComPort Setup

 

Click the down-arrow in the ComPort Setup and then select the active port for the RS232 connection to the T470. 

Connect

 

(Verify that the red LED above the OFF key on the T470 is illuminated.) 

Click on the “Connect” button. 

The red LED will flash quickly 5 times and the Status window will show a “Controller is now connected” message.  

Get Configuration

 

Clicking on the “Get Config” button will fetch the current T470 configuration.  

The “Progress” bar will show this loading, and the “Status” window should show “Config downloaded successfully”.  

The current T470 configuration is then shown in all data/status windows: 

 

The 

Current Device

 code: a 4-digit number in the top setup windows. The current ID is shown in a window, 

and is marked as “Invalid Code” if it is not recognised, or during entering codes not recognised so far as digits 
are entered. The text window below the four code-setting buttons shows the current target display device; 

 

The pre-set 

Keypad

 code, in red at the top of the Keypad layout drawing and the default (or pre-loaded) source 

allocations to each key are shown. 
 
Note: the keypad code is loaded during manufacture, and is not normally field-alterable. The order/invoice 
code used is this keyboard code, with an added letter which identifies the keyboard completely. This gives 
labels such as PC, DVD, TV etc to the ones labelled Source1, Source2, Source3 etc ;  

 

The 

Timer

 settings, either default values (loaded from the internal device data-base) or previously set. These 

are the 

Warm-up Time

, the 

Cool-down Time

, and a couple of internal timers, rarely needing adjustment; 

 

The 

RES

 pin allocation. Choices are: 

PIR

IR Out,

 or 

Relay 3 Out. 

 
In 

PIR

 mode, the T460 senses the presence of people in the room (sensing body heat, via IR) If detected, an 

internal “PIR Run Timer” is reset repeatedly, and no display device turnoff is triggered. However, if everybody 
leaves the room, the PIR Run Timer will timeout after the set time, and the display device is turned off. IN this 
mode, the PIR output contact is wired between the RES pin and Ground. It is internally pulled up by a 4k7 
resistor in this mode. 
 
In 

IR Out

 mode, IR pulses are transmitted from the RES pin on the back of the T470, and assume a positive, 

current-limited voltage is pulsed to an external LED (returned to the Ground pin). This can control a display 
device or ancillary equipment such as a Set Top Box, DVD player, external IR controlled audio system, etc. 
This can be modulated at 38kHz to normal IR-controlled devices, or be unmodulated, e.g. to connect 
electrically to a CommBox LCD display (into a special 3.5mm jack socket). 

Serial 2 out:

 As at V070 a second 

serial port can output serial messages to, for example a scalar/switcher, attached to the RES pin. This option is 
also selected by “IR Out” mode of the RES pin. See User Manual part C for more details. 
 
In 

Relay 3 Out

 mode, the RES can source a 5 volt signal to an external opto-isolated 240 volt relay, an opto-

isolated DC relay or a N-channel power FET (e.g. MTD3055, available from JED) (gate to pin, source to 
ground, drain as output) as a solid-state relay control device. Commercial 240V AC or 60 volt DC opto-relays 
are available from Element 14: see 

http://www.farnell.com/datasheets/77538.pdf 

 They are made by Opto22, 

Gordos, etc and operate with 3.0 volts at 2mA into the internal opto-isolator LED

;

 

 

The 

PIR Run-Timer

 value, the time at which a reset to the OFF state occurs if no-one is sensed by the PIR 

(Passive Infra-Red) detector wired to the RES pin (only valid/active if the RES Pin allocation is to “PIR” use); 

 

The 

Max Volume

 window, which defaults to a data-base preset value, but can be altered, if, for instance, a 

particular installation has a lower maximum value requirement. (Also, this accommodates the sometimes 
incorrect Max Volume setting by some manufacturers). If the projector uses increment/decrement volume 
commands (instead of absolute commands) 

Max Volume

 is locked at 0; 

 

The 

Reply Mode

 setting. If “Greyed-out”, Reply Mode is not available for the currently selected display 

device. If available, a selection can be made. If set to “Off”, it is turned off. 
 
If set to “On”, the T470 will interrogate the current running state of the display device every 5 seconds, and 
will reset itself to the Off state if the display device has assumed the Off state, either because of a time-out or 

Summary of Contents for T470

Page 1: ...New Zealand market Current consumption is approximately 50mA Connections and wiring to the T470 are covered in the later part of this manual page 6 Setting up the T470 To set up the T470 it is necess...

Page 2: ...red between the RES pin and Ground It is internally pulled up by a 4k7 resistor in this mode In IR Out mode IR pulses are transmitted from the RES pin on the back of the T470 and assume a positive cur...

Page 3: ...t to a phantom demo training mode Clicking on Factory Reset will select a default phantom display device Code 0000h which is quite useful for demo and testing purposes It sets valid English language m...

Page 4: ...tton of type which needs a 2 second contact closure on the first line to a common ground to lower the screen and a contact closure on a second line to ground to raise it Assumes limit switches set tra...

Page 5: ...device on time 21 On with On press Off at end of Cool down This is designed to drive a dipper which drops on relay closure and withdraws on relay open This allows full cool down while projector is des...

Page 6: ...3 Source Key 4 Actioned 44 Source Key 5 Actioned 45 Source Key 6 Actioned 46 Source Key 7 Actioned 47 Source Key 8 Actioned 48 Source Key 9 Actioned Hardware connections to T470 The T470 mounts into s...

Page 7: ...y connector only option This allows wiring to the screw terminals of power RS232 and IR out PIR in with nothing connected to the CAT5 connector Connection Function Gnd Ground Tx RS232 from T470 to pro...

Page 8: ...outputs Relays they are actually solid state N FET transistors whose Source is connected to the common Ground of the system and Drain to the output terminal When OFF they are high impedance and when...

Page 9: ...ion Res Pin must be configured for IR Out Connect IR Emitter as shown below Optional Jed IR Emitter is supplied with 2m of cable this can be extended and has been tested with 50m of CAT6 but care must...

Page 10: ...T470 Part A User s Manual Jed Micro Pty Ltd Page 10 Mounting bracket for T470...

Reviews: