background image

Lock: To prevent changes from inadvertently occurring by 
accidentally knocking the adjustable control knob, press and hold the 
'SPEED/LOCK' button for 5 seconds. The red 'LOCK' light will 
illuminate and the control knob will no longer function. Press and 
hold the 'SPEED/LOCK' button for a further 5 seconds to disable this 
feature.

Night: When the two-pinned light sensor is inserted into the small 
socket on the left-hand side of the control box, night mode will 
function automatically. The sensor detects when the tank lights go 
out and slows the pump to half speed. The 'Sensor' LED will 
illuminate when night mode is in operation.  To disable the night 
mode function, remove the sensor from the control box.

Maintenance:             

Regularly clean the outer parts to ensure effective action

Use a dry cloth to prevent water from entering the controller box

To disassemble the wave maker for cleaning - disconnect power, 

remove the pump from the cradle and whilst holding the rear 
section of the pump turn the front grid by rotating it clockwise - see 
images below:

To re assemble, reverse the disassembly instructions.  Be sure when 

fitting the front grid that the ceramic shaft is located into the 
bearing.  Once in position, turn the front grid clockwise until you 
hear a loud click, indicating that the pump is assembled correctly.

Disposal:

 Do not dispose this product as unsorted municipal waste. 

Collection of such waste separately for special treatment is necessary.

Jebao Co., Ltd.
Tongmao Industrical Park, Dongsheng, Zhongshan, Guangdong. China.
Email:[email protected]              
Website: www.jebao.com
Tel: +86-760-22212306, 22212307      
Fax:+86-760-22212368

Front grid to remove

Hold this section firmly

Rotate front section 
anti clockwise

Pump disassembled

WP-40 =130mm
WP-25 = TBC

WP-40 = 100mm
WP-25 = TBC

Reviews: