background image

 
 

 

 

Quick Start

 

1.

 

Setting of Programming Switch : On the side 
of  the  main  unit  there  is  a  programming 
switch  (Fig.1)  with  5  slide  levers,  please 
refer  to  Fig.4,  find  your  pump’s  model  and 
set  the  slide  levers  accordingly.  Please  visit 
www.coral-box.com for latest support list

 

 

2.

 

Connection to Variable Speed Control Unit : 
Use  a  RJ45  cable  to  connect  to  the  main 
unit’s  RJ45  8P  socket.  The  pin  definition  of 
the  RJ45  socket  is  as  on  Fig.2.  They  are  0  – 
10VDC  input,  applying  voltage  out  of  this 
range  will  damage  the  unit  permanently. 
CH1  1  –  10V  corresponding  to  10  –  100%, 
and  CH2  having  no  connection  or  lesser 
than  2VDC

the  pump  will  be  in 

default/clockwise  direction,  else  if  voltage 
of  more  than  8VDC,  the  pump  will  rotates 
reversely

 

 

3.

 

Connection to Your Aquarium Pump : As on 
Fig.3,  connect  your  pump to the  AQLink  A1 
“PUMP” cable

 

 

4.

 

Connection  to  Power  Supply  :  Power  off   
your  original    pump  /  wave  maker  DC 
adapter, and then connect to AQLink A1 DC 
jack input, the jack polarity is as below :

 

 

 

5.

 

Finally, switch on the input power of the DC 
adapter,  the  green  LED  will  light  up 
indicating the unit start to operate normally

 

Fig.2 RJ45 Socket

 

 

 

Fig.3 Pump and Power

 

Fig.1 Programming Switch

 

Reviews: