32
8.
Then adjust the feed conveyor speed so that the bale rotates continuously on the feed
conveyor, and depending on the rate of feed of silage into the chute.
a.
Note:
b.
If the blower unit is not fitted with a fluid flow regulator, feed conveyor speed
adjustment is achieved using the tractor’s hydraulic spool valve or the pump
regulator if fitted.
c.
If the blower is fitted with a fluid flow regulator, use the electric - + push-
button to reduce or increase speed.
9.
Always maintain a speed of 540 rpm until the end of the operation to avoid wrap-
around the shredder.
10.
Check that the round bale is turning regularly; adjust the feed conveyor speed if
necessary to maintain regular rotation; maintain the highest possible feed conveyor
speed.
11.
If the straw blower is fitted with a rotating outlet chute, use this function to vary the
trajectory in the horizontal plane. Rotate it smoothly and carefully.
11. Additional equipment information
1- Hydraulic flow divider for tractor flow rates exceeding 45l / min (Ref tarif 8958) N°
824403
-
To be fitted between the tractor pressure outlet and pressure inlet on the straw blower’s
hydraulic spool valve.
2- 1 m DOOR EXTENSION (Ref tarif 91565)
SAFETY
To be bolted firmly to the rear access door.
Adjust the door actuator attachment plate so that the door extension touches the ground when
the unit is lowered to the ground.