30
4- WHEN THE SPREADING IS FINISHED
After unloading, never forget:
1.
To stop the moving floor
.
- With hydraulic control from the tractor, cut the spreader’s power by putting the
tractor distributor into neutral.
- With independent hydraulic control, put the spreader’s distributor in neutral, halt.
2.
To stop the rotor using the PTO.
3.
To close the guillotine door. The door should never remain open during transfers.
4.
To cut the tractor’s hydraulic circuit.
5.
To reduce the speed of the moving floor using the moving floor regulator.
12. Additional equipment information
1 – INDEPENDENT HYDRAULIC POWER UNIT (Price ref 2236)
1- PUMP, MODEL 540 revs/min EVR 8-6 10-6 12-8 13-10 15-12 N° 821019
2- PUMP, MODEL 1000 revs/min EVR 14-11 14-12 16-12 18-14 21-15 N° 821020
SAFETY
As the pump is driven by the rotating PTO, do not forget to put the control distributors for
hydraulic parts in neutral such as the moving floor, heavy slurry door…etc.
FUNCTION
Avoids using the tractor’s hydraulic circuit.
USE
1.
Activate the tractor’s PTO.
2.
Regularly check the oil level which should be displayed on the reservoir indicator.
MAINTENANCE
1.
Empty the reservoirs once a year:
2.
Quality of oil:
Mineral oil
HFO 32
UNIL -
OPAL
formerly HYDRO 32
3.
Quantity of oil
49 litres
Between the 2 indicators – level