The air conditioning is running:
- Switch the air-conditioning circuit-breakers ON.
- Select the temperature of each compressor using the control units.
- Refer to manufacturer's instructions for use and maintenance.
- When the air-conditioning is running, check visually that the sea water has
been fully drained.
- Never start the generator when the climate function is already on.
- Always turn off the air conditioning before turning off the generator.
- Regularly check and clean the sea water filter placed on the sea water intake
through-hull fitting.
- Close the sea water intake valve ;
- Unscrew the top of the filter ;
- Clean the strainer ;
- Put everything back in place.
- Clean the air filter (located in the compressor) regularly for maximum
performance of the installation.
- Clean the cooling coil at least once a year.
- To prevent the air-conditioning circuit from freezing: never run the system
when the seawater temperature drops below 5 degrees C.
- Winter Storage: drain the whole sea water system.
- The cooling gas circuit needs no maintenance.