For Layer 3 IPv4 testing, configure the following additional settings: 

Folder 

Option 

Value(s) 

Comment 

IP 

Source IP Type 

Static 

Options displayed after tapping 
Source IP Address field.  

Source IP 

See Work Order 

Default Gateway 

See Work Order 

Subnet Mask 

See Work Order 

Destination IP 

See Work Order 

Options displayed after tapping 
Destination IP Address field.  

 
11.

 

View Results 

Press the 

RESULTS

 button, to display the Results screen. 

 

12.

 

Turn Laser On 

If testing an Optical link, select the Laser tab in the lower part of the 
screen and press 

Laser Off

.  The button will turn Yellow and be 

relabeled to indicate the 

Laser

 is 

On

 

13.

 

Check LEDs 

Press the 

Restart 

soft key on the Right side of the display to reset test 

results.  A 

Green

 Signal Present LED indicates that the T-BERD is 

receiving an optical signal from the near end Ethernet Switch.  

Green

 

Sync Acquired

 and 

Link Active

 LEDs indicate that the T-BERD has 

successfully connected to the near end Ethernet switch and the Ethernet 
link is active.   
 

14.

 

Check ARP Status 

If you are running a 

Layer 3 IPv4 Test

, verify that the final message in 

the Message bar is “ARP Successful.  Destination MAC obtained.”  If 
the message bar displays: “Messages logged,” tap the down arrow next 
to “Messages logged” and verify that the final message is “ARP 
Successful.  Destination MAC obtained.” Click OK to exit the log. 

If “

ARP Successful”

 is not displayed, verify that the T-BERD’s IP menu 

is configured correctly, as outlined above. 
 

15.

 

Start RFC 

Press the 

Enhanced RFC 2544 

soft key on the Right side of the 

Results

 

screen. 

 

16.

 

Select Config 

Select the 

Configs

 tab.  If this is the first time using the RFC2544 test, 

tap 

[New]

, enter a name for the new configuration, then tap 

[OK]

.  

Otherwise, choose the saved Test Configuration. 

 

 

Summary of Contents for T-BERD 6000A

Page 1: ...Page 1 of 28 Technical Support tac jdsu com 1 866 228 3762 Systems Engineer Dave Baker jdsu com 321 243 0600 JDSU T BERD 6000A RFC 2544 Ethernet Testing Guide Version 1 0 December 19 2011...

Page 2: ...for Metro Ethernet service up to 1 Gbps including Layer 2 and Layer 3 IPv4 RFC 2544 tests between two T BERD 6000A s Layer 2 and Layer 3 IPv4 RFC 2544 tests between the T BERD 6000A and T BERD 5800 L...

Page 3: ...ed to validate the performance of an Ethernet circuit and to verify conformance to the agreed upon Service Level Agreement SLA 1 1 Hardware Description The T BERD 6000A is a portable test tools for Et...

Page 4: ...Gbps links Layer 2 and Layer 3 IPv4 testing JDSU T BERD 6000A T BERD 5800 and HST 3000 loopback devices Procedures are described for RFC 2544 Tests to verify throughput round trip delay jitter and fra...

Page 5: ...roximately 1 minute for the Base Unit software to load 4 Launch MSAM Press the SYSTEM button The MSAM is represented by a BERT icon on the upper image of the test set If the BERT icon is not already h...

Page 6: ...Reset to Defaults In the Tools menu select Reset Test to Defaults Press OK to continue 10 Setup Press the SETUP soft key on the top right side of screen Select the indicated folders and configure you...

Page 7: ...sults A Green Signal Present LED indicates that the T BERD is receiving an optical signal from the near end Ethernet Switch Green Sync Acquired and Link Active LEDs indicate that the T BERD has succes...

Page 8: ...s Zero in Process JDSU Enhanced Trial Duration seconds 60 Frame Loss Tolerance 0 Show Pass Fail Status Selected Throughput Threshold Mbps See Work Order for CIR Setup Latency RTD Number of Trials 1 Tr...

Page 9: ...BERD will loop up the far end unit and test Throughput Delay Jitter and Frame Loss The test will take 6 to 9 minutes to complete At the conclusion of the test the T BERD 6000A will automatically loop...

Page 10: ...mary tab to view status of all tests Verify that all tests PASS and the displayed values meet the performance objectives of the line under test 22 Exit Tap Exit to return to the main Results view 23 R...

Page 11: ...mately 1 minute for the Base Unit software to load 4 Launch MSAM Press the SYSTEM button The MSAM is represented by a BERT icon on the upper image of the test set If the BERT icon is not already highl...

Page 12: ...ptical Testing Ethernet 1GigE Optical Layer 3 Traffic IPv4 Terminate 9 Reset to Defaults In the Tools menu select Reset Test to Defaults Press OK to continue 10 Setup Press the SETUP soft key on the t...

Page 13: ...e Right side of the display to reset test results A Green Signal Present LED indicates that the T BERD is receiving an optical signal from the near end Ethernet Switch Green Sync Acquired and Link Act...

Page 14: ...sting insert desired SFP 1000BASE SX 1000BASE LX or 1000BASE ZX in the desired T BERD 5800 s SFP port 3 Clean Inspect While the BERT module is starting up and before connecting to an optical link make...

Page 15: ...he SETUP soft key on the top right side of screen Select the indicated folders and configure your test as follows Leave all other values at default unless specified in the Work Order Folder Option Val...

Page 16: ...end Ethernet Switch Green Sync Acquired and Link Active LEDs indicate that the T BERD has successfully connected to the near end Ethernet switch and the Ethernet link is active 11 Check ARP Status If...

Page 17: ...o load 3 Insert SFP For optical testing insert desired SFP 1000BASE SX 1000BASE LX or 1000BASE ZX into the optical SFP connector labeled R T 1 4 Clean Inspect While the BERT module is starting up and...

Page 18: ...ayer 2 Traffic at the Test prompt For Layer 2 Optical Testing press the ETH OPTIC Soft key select 1G Terminate and press the OK key Select Layer 2 Traffic at the Test prompt For Layer 3 IPv4 Electrica...

Page 19: ...t Arrow key until LED Results are displayed A Green Signal Present LED indicates that the HST 3000 is receiving an optical signal from the near end Ethernet Switch Green Sync Acquired and Link Active...

Page 20: ...600 12 Check ARP Status If you are running a Layer 3 IPv4 Test verify that the final message in the Message bar is ARP Successful If ARP Successful is not displayed verify that the HST 3000 s IP menu...

Page 21: ...benchmarking methodology The RFC 2544 procedure outlined in Section 2 should be completed prior to RFC 6349 testing Test procedures are described for Electrical and Optical handoffs 10Mbps 100Mbps and...

Page 22: ...cedure to set up a T BERD 6000A to test TCP Throughput Step Action Details 1 Select Test For electrical handoffs In the Test menu at the top of the Results screen and select Ethernet 10 100 1000 Layer...

Page 23: ...x See Work Order Options only displayed if Auto Negotiate Off Speed For Optical handoffs Select the indicated folders and configure your test as follows Folder Option Value s Comment Interface Connect...

Page 24: ...Order For Layer 2 handoffs set to None Connect to Port 5001 Source IP Type Static Source IP See Work Order For Layer 2 handoffs set to 192 168 1 2 Default Gateway See Work Order For Layer 2 handoffs...

Page 25: ...Duration 30 Setup Traffic Shaping Duration seconds 30 Other Traffic Shaping fields will be autopopulated by the TrueSpeed application Setup TCP Throughput Window Size Set as close as possible to the I...

Page 26: ...e prompt Select the Append option and tap Yes to save the test report to the T BERD 6000A hard drive in PDF format The filename including a time and date stamp will be displayed in the Progress log 13...

Page 27: ...ure to set up a T BERD 6000A as a TCP Server Step Action Details 1 Select Test For Electrical handoffs In the Test menu at the top of the Results screen and select Ethernet 10 100 1000 Layer 4 TCP Wir...

Page 28: ...value as Ethernet switch port For all handoffs Select the indicated folders and configure your test as follows Leave all other values at default unless specified in the Work Order Folder Option Value...

Reviews: