Chapter 4
E1 Testing
Pulse shape analysis
42
SmartClass E1 Tester User’s Guide
Pulse shape analysis
You can use the Pulse Shape feature to measure the height, width, rise time,
fall time, overshoot and undershoot, and signal level of an E1 pulse. The
results are displayed as text or as a graph of the pulse shape. You can also
measure the pulse for conformance to ITU G.703 specifications.
To perform pulse shape analysis
1
If you haven’t already done so, launch the E1 Pulse Shape test application
(see
“Launching an E1 test application” on page 28
2
From the E1 Pulse Shape menu, select
Configuration
.
The Configuration menu appears.
3
Connect the E1 Tester to the test access point, using the RX/TX1
connector.
4
To configure the test, do one of the following:
– If you want the E1 Tester tester to configure the interface, framing, and
pattern settings automatically, on the test menu, select
Action
, and
then select
Auto Configure
.
The unit will attempt to automatically configure the interface, framing,
and pattern. If the Auto Configure succeeds, proceed to
.
If this attempt fails, the E1 Tester will continue it’s attempt to configure
the framing settings, and the pattern will default to Live. You can also
configure the setting manually by selecting
Configuration
, and then
.
– If you want to configure the interface, framing, and pattern settings
manually, on the test menu, select
Configuration
, and then proceed
with
5
Configure the interface settings. See
“Specifying interface settings” on
6
Configure the E1 framing settings. See
“Specifying E1 framing settings” on
7
Configure the E1 ABCD/Sa settings. See
“Specifying E1 signaling (ABCD/
8
From the E1 Pulse Shape menu, select
Results
and then select one of the
following:
–
Summary
displays a large “All Summary Results OK” message if no
anomalies or defects have been detected. If anomalies are detected,
results are displayed.
–
Pulse Shape
displays a graphical representation of the pulse.
NOTE:
Pulse Shape is an optional feature. It only appears if you have purchased
the pulse shape software option.
Summary of Contents for SmartClass E1
Page 1: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 2: ......
Page 3: ...SmartClass E1 and E1 Datacom Testers User s Guide...
Page 6: ...iv SmartClass E1 Tester User s Guide...
Page 12: ...Table of Contents x SmartClass E1 Tester User s Guide...
Page 16: ...About this Guide Conventions xiv SmartClass E1 Tester User s Guide...
Page 32: ...Chapter 1 Getting Started Using the keypad 16 SmartClass E1 Tester User s Guide...
Page 38: ...Chapter 2 Instrument Settings Restoring factory defaults 22 SmartClass E1 Tester User s Guide...
Page 66: ...Chapter 4 E1 Testing Testing MFC R2 Signaling 50 SmartClass E1 Tester User s Guide...
Page 118: ...Chapter 7 Test Results Viewing saved results 102 SmartClass E1 Tester User s Guide...
Page 143: ......