background image

Assembly 

5.

Mechanical assembly 

5.1.

After unpacking inspect for transport damages 

Damaged parts must not be installed 

Check if JHBEX meets requirements of 

your  Ex-zone 
During installation zone release must be ensured 

JHBEX must be coated with heat-transfer paste on 

the contact surface. Application temperature of the 
heat-transfer paste must fit to the temperature class 
of the JHBEX typeplate. 
Screw the JHBEX with full surface contact. 

Recommended tightening torque max. 2.4 Nm. 
 

 
 

Electrical connection 

5.2.

Ensure zone clearance during assembly. 

Compare the local mains voltage, mains frequency 

and power consumption with the specifications on 
the type plate. 
Connect the JHBEX in accordance with the locally 

applicable regulations and additionally ground it via 
the ground connection on the housing using a con-
ductor with a cross-section of at least 4 mm². 
Correct connection is operator responsibility. 

Junction box with type of protection increased safety 

for the corresponding zone is recommended. 
Strip the connection cable only up to a minimum of 

300 mm, measured from the cable gland. 
(see figure on page 14). 
Exposed strands may be shortened as required by 
the customer. 
Observe minimum bending radius of 29 mm for fixed 

mounted cable or 55 mm for moveable cable. 
Do not damage the individual wires of the cable 

when stripping (notch). 
Finishing the cable ends in accordance with the  

regulations and connect them in a suitable terminal 
box. 
Install strain relief for connection cable on the  

terminal box. 
Tighten the union nut of the cable gland.  

Recommended tightening torque 20 Nm. 

 

Montage 

5.

Mechanische Montage 

5.1.

Nach dem Auspacken auf Transportschäden 

untersuchen 
Beschädigte Teile dürfen nicht verbaut werden 

Überprüfen, ob der JHBEX den Anforderungen 

Ihrer Zoneneinteilung entspricht 
Während der Montage ist die Zonenfreigabe 

sicherzustellen 
Der JHBEX ist an der Auflagefläche mit Wärmeleit-

paste zu bestreichen. Temperaturbeständigkeit der 
Wärmeleitpaste muss der Temperaturklasse am 
Typenschlid des JHBEX entsprechen. 
Den JHBEX vollflächig anliegend verschrauben. 

Empfohlenes Anzugsmoment max. 2,4 Nm. 

 

Elektrischer Anschluss 

5.2.

Während der Montage Zonenfreigabe  sicherstellen. 

Örtliche Netzspannung, Netzfrequenz und Leis-

tungsaufnahme mit Angaben am Typenschild  
vergleichen. 
JHBEX entsprechend den örtlich geltenden 

 Vorschriften anschliessen, sowie zusätzlich über 
den Erdungsanschluss am Gehäuse, mit einem Lei-
ter von mindestens 4 mm² Querschnitts, erden. 
Der Betreiber ist für den korrekten Anschluss 

verantwortlich. 
 Anschlussdose mit Zündschutzart erhöhte 

Sicherheit für die entsprechende Zone wird 
empfohlen. 
Das Anschlusskabel nur auf ein minimal 300 mm 

abisolieren (siehe Skizze auf Seite 14). 
Freiliegende Litzen können nach Kundenwunsch 
gekürzt werden. 
Mindestbiegeradius von 29 mm für fix installiertes  

Kabel und 55 mm für bewegtes Kabel ist  
einzuhalten. 
Einzeladern des Kabels beim Abisolieren nicht  

beschädigen (einkerben). 
Kabelenden vorschriftsgemäß endversogen und in 

einer ge eigneten Klemmdose anschließen 
Zugentlastung für Anschlusskabel an der Klemmen-

dose installieren. 
Überwurfmutter der Kabelverschraubung nachzie-

hen. Empfohlenes Anzugsmoment 20 Nm. 

BA_JHBEX_v1.21              

                        ––––––––––––––– 

[ 10 / 15 ]

 –––––––––––––––––

Manual       JHBEX

Summary of Contents for JHBEX

Page 1: ...JES 360 JES 360H Date Stand 03 21 OPERATING MANUAL BEDIENUNGS ANLEITUNG OPERATING MANUAL BEDIENUNGS ANLEITUNG JHBEX Date Stand 04 22 Heizblock für Ex Zonen Heating Block for Ex zones ...

Page 2: ...rface 7 2 3 1 JHBEX with round contact surface 7 2 3 2 JHBEX with flat contact surface 7 3 Technical data 8 4 X requirements Specific comment for use 8 5 Assembly 10 5 1 Mechanical assembly 10 5 2 Electrical connection 10 6 Start up 11 7 Maintenance 12 8 Dismantling 13 9 Fault diagnostic 13 10 Recycling Disposal 13 11 Dimensions 14 11 1 JHBEX with round heat transfer surface 14 11 2 JHBEX with fla...

Page 3: ...o hand over these operating manual as well as they are an essential part of the product Explanation of symbols 1 2 If a section of text is marked with one of the following warning symbols the danger described in the text must be avoided in order to prevent the possible consequen ces described there General safety information 1 3 The JHBEX is a device for usage in for use in potentially explosive a...

Page 4: ...htbeachtung kann zu Sach und oder Personenschäden führen Bei Nichtbeachtung der Sicherheitsvorrichtungen und der in dieser Betriebsanleitung aufgeführten Warn Hinweise übernimmt JCT keine Haftung Dies gilt sowohl bei der Installation beim Betrieb als auch bei Wartung Auch dann wenn in dieser Bedienungs und Wartungs anleitung nicht ausdrücklich darauf hingewiesen wird JCT haftet nicht für eigenmäch...

Page 5: ...0 ATEX E 029 X II 1 2D Ex tb Da IIIC T230 C Db Gb BVS 20 ATEX E 029 X Ex db Ga IIC 230 C T2 Gb IECEx BVS 20 0023X Ex tb Da IIIC T230 C Db IECEx BVS 20 0023X 2000 Zone 1 21 Zone 0 20 T3 T 200 C 60 C 150 C II 1 2G Ex db Ga IIC T3 Gb BVS 20 ATEX E 029 X II 1 2D Ex tb Da IIIC T200 C Db BVS 20 ATEX E 029 X Ex db Ga IIC T3 Gb IECEx BVS 20 0023X Ex tb Da IIIC T200 C Db IECEx BVS 20 0023X 1350 Zone 1 21 Z...

Page 6: ...zone 1 21 zone 2 22 2 zone 2 22 Montagefläche Mounting surface gebogen R round gerade F flat Befestigung Mounting ohne Montagelöcher 0 without mounting holes 2 Montagelöcher 2 2 mounting holes 4 Montagelöcher 4 4 mounting holes ANSI ISA SP76 standard 6 ANSI ISA SP76 standard Kabellänge Cable length 3 m L1 3 m 10 m L2 10 m 0 5 m L3 0 5 m 1 m L4 1 m Kabelverschraubung Cable gland nicht für Panzerroh...

Page 7: ...ng Wärmeableitung über Kabelverschraubung verboten Heat discipitation over cable clamp prohibited Anschluss für Erdung M5 Gewinde Grounding position M5 thread Wärmetransferfläche Muss vor Montage mit Wärmeleitpaste dünn bestrichen werden Heat transfer surface Must be coated thinly with heat conductive paste before mounting Anschluss für Untertemperaturkontakt M3 Gewinde max 7 tief Mounting positio...

Page 8: ...t werden wo die Wärmeabgabe des Heizblocks über Pmin liegt Der Nachweis dazu kann rechnerisch oder durch Messung erfolgen Bei Bedarf können JCT Techniker unterstützen Pmin Watt 0 25 Umgebungstemperatur C 101 Construction Mounting position coat the contact surface with heat transfer paste and apply it to the en tire surface Weight 0 4 kg Body material aluminium Housing color yellow Heating element ...

Page 9: ... block JHBEX 1352xxxxx There are no additional requirements for this heating block Wärmeableitung über Kabelverschraubung verboten JHBEX 2000xxxxx Der Heizblock darf nur auf eine thermische Last aufge schraubt betrieben werden Leistungsabgabe mindestens 35W Wärmeableitung über Kabelverschraubung verboten JHBEX 1350xxxxx Der Heizblock darf nur auf eine thermische Last aufge schraubt be trieben werd...

Page 10: ...box Tighten the union nut of the cable gland Recommended tightening torque 20 Nm Montage 5 Mechanische Montage 5 1 Nach dem Auspacken auf Transportschäden untersuchen Beschädigte Teile dürfen nicht verbaut werden Überprüfen ob der JHBEX den Anforderungen Ihrer Zoneneinteilung entspricht Während der Montage ist die Zonenfreigabe sicherzustellen Der JHBEX ist an der Auflagefläche mit Wärmeleit paste...

Page 11: ...annung übereinstimmen HINWEIS Die Farbe des JHBEX kann sich nach dem Auf heizen geringfügig verändern Das hat keinen Einfluss auf die Funktion WARNING Disconnect the power supply when working on the device Secure against being switched on again Check that no voltage is present Ground and short circuit Cover or isolate adjacent live parts CAUTION The device gets very hot during operation During any...

Page 12: ...red wait for cool down tighten the screws Recommended tightening torque max 2 4 Nm Wartung 7 Der JHBEX ist grundsätzlich wartungsfrei Es wird empfohlen den JHBEX nach 5 Jahren Betriebs dauer zu tauschen um dauerhaft die Funktion zu ge währleisten Im Rahmen der regelmäßigen Kontrollen ist folgendes zu überprüfen Visuelle Kontrolle auf Beschädigungen von Kabelverschraubung JHBEX und Anschlusskabel S...

Page 13: ...nik GmbH zu schicken Dazu ist das RMA Formular auf unserer Web site vollständig auszufüllen www jct at rma Andernfalls kann das Gerät zum Schutz der JCT Mitarbeiter nicht übernommen werden Fehlerdiagnose 9 Recycling Entsorgung 10 Entsprechend Richtlinie 2012 19 EU ist das Gerät am Ende seiner Lebensdauer einer geordnetenn Entsorgung zuzuführen Das Gerät enthält Bauteile die wiederverwertet werden ...

Page 14: ...Wärmetransferfläche 11 1 JHBEX mit flacher Wärmetransferfläche 11 2 BA_JHBEX_v1 21 14 15 Manual JHBEX JCT 108 L min 300 35 R 4 0 6 6 6 6 30 30 M3 m ax 7m m 7 O 3G 1mm Erdungsanschluss M5 max 3 5Nm 33 142 O 4 5 O 4 5 24 SW 108 142 29 50 min 300 L 35 2 4 S W Erdungsanschluss M5 max 3 5Nm 24 24 6 6 6 O 4 5 M 3 m a x 7 m m 7 O 3G 1mm O 4 5 ...

Page 15: ...ct at wp content uploads 2021 03 JHBEX_Dekra_BVS 20 ATEX E 029 X_EU Type Examination Certificate 1 pdf Beheizung in ZONE 1 und oder einwirkend auf ZONE 0 https jct at wp content uploads 2021 03 JHBEX_Dekra_BVS 20 ATEX E 034 X_EU Type Examination Certificate 1 pdf Beheizung in ZONE 2 https jct at wp content uploads 2021 03 JHBEX_IECEx_BVS_20 0023_000 pdf https jct at wp content uploads 2021 03 JHBE...

Reviews: