*1...Mounting material is included
Subject to change without notice
Mounting
4.1.
The complete unit consists of the heated filter head, tem-
perature controller, mounting flange, valves and instal-
lation material. Mounting can be done in a horizontal or
vertical position. The probe´s design fits for mounting di-
rectly to a standard flange. If the assembly takes place
horizontal, the JES-360 should be built in an angle at
least between 5° and 15° from the horizontal falling, to
allow condensate flow back into the process.
Versatile
4.2.
Different sample pipe materials, electrically heated sam-
ple pipes and large pre filters make the JES-360 very
flexible for different applications.
Service and security
4.3.
A temperature status contact signalizes fault and low
temperature, an over temperature protection avoids
overheating. Filter replacement can be done easily wit-
hout any tools and without disconnecting the heated
sample line.
Manual JES-360/JES-360h
*1…Befestigungsmaterial wird mitgeliefert
Technische Änderungen vorbehalten
Montage
4.1.
Die Gasentnahmesonde besteht aus dem beheiztem Fil-
terkopf, Temperaturregler, Montageflansch, Ventilen und
Montagematerial. Sie kann horizontal oder vertikal mon-
tiert werden. Die Sonde wird direkt an einem Standard-
Prozessflansch montiert. Wenn die Montage horizontal
erfolgt, sollte die JES-360 zumindest zwischen 5° und
15° aus der horizontalen fallend eingebaut werden,
damit anfallendes kondensat zurück in den Prozess ab-
geleitet werden kann.
Modular
4.2.
Unterschiedliche Entnahmerohrmaterialien, elektrisch
beheizte Entnahmerohre und große Vorfilter machen die
JES-360 anpassungsfähig für verschiedenste Applika-
tionen.
Service und Sicherheit
4.3.
Ein Statuskontakt signalisiert Störung und Untertempe-
ratur, eine Übertemperaturbegrenzung schützt vor Über-
hitzung. Der Filterwechsel kann ohne Werkzeug und
ohne Demontage der beheizten Messgasleitung durch-
geführt werden.
BA_DE_JES360_v1.01
–––––––––––––––
[ 11 / 34 ]
–––––––––––––––––
Construction
Dimension over all
with all variants
260 x 419 x 440 mm WxhxD
696 x 645 x 440 mm WxhxD
Junction box
120x160x90 mm hxWxD
Dead volume
180 cm
3
Mounting flange *1
Option
DN 65, PN 6, form A according
to EN 1092-1; SS316
2“ANSI; 150lbs., hole pattern
according to ASME B16.5
Mounting angle
range 5° to 15° with respect to the
horizontal, sloping down
Mounting position
Torsion angle max. 45°
Weight
with all variants
approx. 15 kg
approx. 25 kg
housing material
SS304
housing colour
Stainless steel natural
Sample gas inlet
G3/4“ female thread
Sample gas outlet
1/8" NPT female thread
calibration port
pipe stubs 6 mm, SS316
Back purge port
pipe stubs 6 mm, SS316
Back Flush port
bulkhead fitting, 12mm
heater element
approx. 800 W
Power consumption
approx. 805 VA
Power supply
230 VAc/50 hz or
115 VAc/60 hz; +/-10%
Approval / Sign
cE
Konstruktion
Abmessungen über alles
mit allen Varianten
260 x 419 x 440 mm BxhxT
696 x 645 x 440 mm BxhxT
klemmenkasten
120x160x90 mm hxBxT
Totvolumen
180 cm
3
Montageflansch *1
Option
DN 65, PN 6, Form A nach
EN 1092-1; 1.4401
2“ANSI; 150lbs.; Lochbild
nach ASME B16.5
Einbauwinkel
Empfohlen 5° bis 15° aus der
horizontalen fallend
Einbaulage
Verdrehwinkel max. 45°
Gewicht
mit allen Varianten
ca. 15 kg
ca. 25 kg
Gehäusematerial
1.4301
Gehäusefarbe
Edelstahl natur
Messgas Eingang
G3/4“ Innengewinde
Messgas Ausgang
1/8“ NPT Innengewinde
kalibriergasanschluss
6 mm Rohrstutzen, 1.4401
Anschluss für Rückspülung
6 mm Rohrstutzen, 1.4401
Anschluss für Back Flush
Schottverschraubung, 12mm
heizelement
ca. 800 W
Leistungsaufnahme
ca. 805 VA
Anschlussspannung
230 VAc/50 hz oder
115 VAc/60 hz; +/-10%
Zulassungen / Zeichen