Performance diagrams
5.1.
Manual JCP-300 Series
Leistungsdiagramme
5.1.
BA_DE_JCP-300_v1.0
–––––––––––––––––––––––––– [ 10 ] ––––––––––––––––––––––––––
4,0
5,0
6,0
7,0
8,0
9,0
20 22 24 26 28 30 32 34 36 38 40
Ta
upunk
t
am Messg
asausg
ang [
°C]
Dew point a
t
sample g
a
s
outlet [
°C]
Umgebungstemperatur [°C]
Ambient temperature [°C]
UT Performance - Peltierkühler - 20-40°C - 1 l/min
TP / DP 40°C
TP / DP 55°C
Taupunkt am Messgaseingang
Dew point at sample gas inlet
Messgasfluss 1 l/min
Messgas Eingangstemperatur 140°C
Sample gas flow 1 l/min
Sample gas inlet temperature 140°C
Ersatzteile
K1004600
Ventilator 230 VAC
K1004605
Ventilator 115 VAC
K1204323
Peltier - Regelelektronik JPCU-1
K1204360
Kondensatwächter - Elektronik KW-2
17.04000
Kondensatsensor KW-1
K1250001
Temperaturfühler
K1233002A
Kondensatpumpe komplett
K1233200
Membran-Messgaspumpe 230 VAC
K1233201
Membran-Messgaspumpe 115 VAC
Spare parts
K1004600
Fan 230 VAC
K1004605
Fan 115 VAC
K1204323
Peltier - controller JPCU-1
K1204360
Condensate detector electronic KW-2
17.04000
Condensate sensor KW-1
K1250001
Temperature sensor
K1233002A
Condensate pump complete
K1233200
Diaphragm sample gas pump 230 VAC
K1233201
Diaphragm sample gas pump 115 VAC