1248015-GB_v1.1
ROLLER 868
7
CODE CANCELLATION
TOTAL RESET
In programming mode, the programming button is held down for over 10 sec. The equipment
will issue 10 short acoustic warning signals followed by others at a faster pace to indicate that
the operation has been successful. The equipment is now in programming mode. The pilot
programming light will also follow the acoustic indications by flashing.
After 10 seconds without programming or quickly pressing the programming button, the
equipment will exit programming mode, issuing two 1 sec. acoustic signals.
USE OF THE RECEIVER-PANEL
This receiver-panel is designed for use as a remote control for garage doors.
Its use is not guaranteed for directly activating any other equipment different to that specified.
The manufacturer reserves the right to modify equipment specifications without prior notice.
IMPORTANT SAFETY INSTRUCTIONS FOR INSTALLATION
Disconnect the power supply whenever you proceed
to the installation or repair of the control panel.
· Disconnect the power supply before handing the equipment.
· Before installing the panel, remove all unnecessary ropes or chains and disable any
equipment such as locks that is not necessary for the automatic operation.
· Before installing the panel, check that the door is in good mechanical condition, correctly
balanced and that it opens and closes correctly.
· Install the manual unlocking device at a height lower than 1.8m.
· Install any permanent control next to the door away from any moving part and at a minimum
height of 1.5m.
· An easily accessible disconnection device must be fitted to the wiring for permanently
connected equipment. It is wise for this to be an emergency switch.
· When the equipment is switched on for the first time, check that the first time the start
button is pressed causes the opening movement (and not closure).
· For correct use of the safety edge, this must never be activated when the door is fully closed.
It is wise to install the ends of run before activating the edge.
· This equipment can only be handled by a specialist fitter, by maintenance staff or by a
suitably trained operator.
· To connect the power supply and motor wiring, 3.8 mm2 section terminals must be used.
· Use protective goggles when handling the equipment.
· Fuses must only be handled when the appliance is disconnected from the mains.
· The instructions for using this equipment must remain in the possession of the user.
· European door normative EN 12453 and EN 12445 specify the following minimum
protection and door safety levels:
-
for equipment for residential, commercial and light industry use, prevent the door from
being able to come into contact with any object or limit the contact force (e.g. safety
edge).