JCM ACCESS-1000 Manual Download Page 7

24

25

4- EVENTS

Allows for events to be displayed and deleted.

4.1 SHOW EVENTS

This shows the date and time of the event, the type of event and the code and number of the last event. Using 

 

, all of the 

events can be displayed, moving around by number of events. 

# DATE 

 

TIME

...... ..

TYPE OF EVENT 

CODE >  

EVENT No.

.

Display 

Type of event 

C00   

No event

C01 

Channel 1 reception 

C02   

Channel 2 reception 

C03 

Channel 3 reception 

C04   

Channel 4 reception 

C08 

Attempt at radio programming 

C09   

Anti-panic enabled

C10 

Alarm function enabled 

C11   

Code already entered or exited 

C12 

Code not programmed or disabled 

To exit the menu, press ESC.

4.2 DELETE ALL

Press ENTER and the controller will totally reset the events card and the message OPERATING will appear on the screen. Once the 
operation is complete, OK will appear on the screen.

If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals are given.

ALARM FUNCTION

This function is only configurable using the Assistant programming tool and is only available on proximity elements where the alarm 
function is implemented. 

Allows for the enabling of a different relay to that programmed by default, reading the device a certain number of consecutive times 
in a maximum time of 5 seconds between each reading.  

Example:

 the proximity element enables relay 1 by default and with the alarm function it will enable relay 3 on reading the device 

4 consecutive times. 

MESSAGES

Display 

Type of message

NO 

This appears when a code that is not programmed or that is disabled in the controller is enabled

DATE 

This appears when a proximity element is used outside its validity period. 

NO CREDIT 

This appears when a proximity element is used when no credit is available. 

NO APB 

This appears when the anti-passback does not allow access 

1247005v1-2.indd   24

19/05/2010   11:09:50

Summary of Contents for ACCESS-1000

Page 1: ...COD 1247005 1 2 ACCESS 1000 ACCESS 2000 1247005v1 2 indd 1 19 05 2010 11 09 43...

Page 2: ...tched on Upon receiving a code the equipment checks whether it is in its memory enabling the programmed relay s The position in the memory held by the code received and by the relay s enabling the cha...

Page 3: ...bles relay 4 Example If channel 1 of the transmitter is to be configured to enable relays 1 and 3 numbers 1 and 3 selected using the numeric keys must be displayed on the screen Every time a numeric k...

Page 4: ...r to be programmed and press ENTER When ENTER is pressed the controller checks whether the memory space indicated is available and makes the appropriate registrations showing the sequential codes bein...

Page 5: ...on to be deleted is not programmed the controller will show ERROR 2 on the screen and will return to the menu If no action is made the equipment will automatically exit programming after 60 seconds an...

Page 6: ...Enter the required channel and press ENTER Enter the number to be discounted maximum 4 digits and press ENTER The controller will issue a sound signal to indicate that the operation is being carried...

Page 7: ...e the equipment will automatically exit programming after 60 seconds and two short sound signals are given ALARM FUNCTION This function is only configurable using the Assistant programming tool and is...

Page 8: ...lected time Operations with transmitters Magnetic sensors must be used for card operations with transmitters to be able to distinguish the entry and exit of vehicles to and from an installation Theref...

Page 9: ...d for the power supply connections Use time delayed fuses EC DECLARATION OF CONFORMITY The manufacturer JCM TECHNOLOGIES S A C Bisbe Morgades 46 Baixos 08500 VIC Barcelona SPAIN declares herewith that...

Page 10: ...ACCESS 1000 ACCESS 2000 1247005v1 2 indd 60 19 05 2010 11 09 54...

Reviews: