18
ENGLISH
19
TECHNICAL FEATURES
ACCESS-1000 / ACCESS-2000
Frequency
868.35MHz
Coding
High-security rolling code
Memory
1000 codes (extendible to 2000) / 2000 codes
Events
2000 codes
Number of relays
2 extendible to 4
Anti-panic function
Configurable on the 4 relays (assignable only to 1 relay)
Alarm function
Only available on proximity equipment with alarm function
Power supply
230Vac / 12Vac/dc
Range at 12V dc
11V –- -19V dc
Range at 12V ac
8 V – 14 V ac
Relay contacts
1A
Standby / Op. Consumption
27mA / 57mA to 230Vac
150mA/550mA to 12V ac/dc
Battery
CR 2032 3Vdc (date/time/events)
Access control outlet
BUS-L
(Max. 4 readers without external power supply)
Op. temperature
-20ºC to +85ºC
Watertightness
IP42
Dimensions
170x100x40mm
Box dimensions
220x220x75mm
INSTALLATION AND CONNECTIONS
Fit the rear of the box to the wall using the rawlplugs and screws supplied. Pass the cables through the bottom of the equipment.
Connect the power supply cables to the terminals on the printed circuit, following the indications engraved on the board. Close the
lid on the equipment using the screws supplied.
OPERATING
The name of the controller, the programme version and the date and time will appear on the screen when the equipment is switched on.
Upon receiving a code, the equipment checks whether it is in its memory, enabling the programmed relay/s. The position in the
memory held by the code received and by the relay/s enabling the channel sent by the device are displayed on the screen.
If the device code is not recorded in the memory, the controller will remain motionless and the message “NO” will appear on the
screen.
MENUS
Press any key to enter the menu and the controller will ask for the password. Enter the 4-digit password using the numeric keys. If
the password is incorrect, the message ERROR 1 will appear on the screen and the equipment will issue a sound signal.
The password is written on an adhesive label on the memory card as standard.
The menus displayed will be:
1-
SETUP SYSTEM:
Allows for the following to be configured: date/time, relays, channels and language.
2-
SETUP CODES:
Allows for registrations, cancellations, killpass and discounts to be made
3-
SETUP APB:
Allows for the anti-passback timer to be configured and reset.
4-
EVENTS:
Allows for events to be displayed and deleted.
The menu is changed using
. To validate each option, press ENTER.
Menu movement key
Menu entry key
ENTER
Menu entry or option validation key
ESC
Cancellation Key
If no action is made, the equipment will automatically exit programming after 60 seconds and two short sound signals will be given.
ACCESS-1000 / ACCESS-2000
1247005v1-2.indd 19
19/05/2010 11:09:49