Configuration of transmitter programming in the receiver.

 

Led R1

 

Led R2 

Standard Programming 

(default option, the receiver is always configured on pluri-channel) 

The relays are activated 1st relay by channel 1 and 2nd relay by channel 2 (3rd relay 

by channel 1 and 4th relay by channel 2) 

Flashing Flashing 

Special programming

 

By pressing any transmitter channel, relay 1 on the receiver will be activated 

ON 

OFF 

By pressing any transmitter channel, relay 2 on the receiver will be activated 

OFF 

ON 

By pressing any transmitter channel, the two relays will be activated at the same 

time* 

ON ON 

 

* If working in ON/OFF activation mode, relay 1 will act as impulse and relay 2 as 
ON/OFF. Therefore, on the first press relay 1 will close and open the contact and relay 2 
will only close. On the second, relay 1 will close and open 

the contact and relay 2 will 

open. 
N.B.: Each transmitter can be configured independently on the receiver. 

 

TOTAL RESET 

In programming mode, the programming button is held down and the “MR” reset jumper 
is bridged for 3 secs. The receiver will issue 10 short acoustic warning signals followed by 
others at a faster pace to indicate that the operation has been successful. The receiver is 
now in programming mode. 
After 10 seconds without programming or quickly pressing the programming button, the 
receiver will exit programming mode, issuing two acoustic signals of 1 sec. 

For more information please see our web site www.motion-line.com

 

 

USE OF THE RECEIVER 

These receivers are designed for use as remote controls for garage doors. Their use is not 
guaranteed for directly activating any other equipment different to that specified. 
The manufacturer reserves the right to modify equipment specifications without prior 
notice. 
 

IMPORTANT ANNEX 

Disconnect the power supply before handing the unit. 
In compliance with the European Directive low-voltage electrical equipment, we hereby 
inform users of the following requirements: 
· For units which are permanently connected, an easily accessible circuit-breaker device 
must be built into the wiring system. 
· This unit must always be installed in a vertical position and firmly fixed to the structure of 
the building. 
· This unit must only be handled by a specialised installer, by his maintenance staff or by a 
duly trained operator. 
· The instruction manual for this unit must always remain in the possession of the user. 
· Terminals of maximum section 3,8mm2 must be used for the power supply connections. 
· Use time delayed fuses. 
 

JCM TECHNOLOGIES, S.A. 

declares herewith that the product WAVE500, WAVE500-B 

complies with the relevant fundamental requirements as per Article 3 of the R&TTE 
Directive 1999/5/EG, insofar as the product is used correctly. 
 

 