background image

jcm

technologies

 

8

 

Programming 

Radio Manual Programming (Remote controls, wireless buttons, etc)

 

OPEN TOP

 

 

PRESS RED RPROG

 

PUSHBUTTON 

LED TURNS ON 

PRESS TRANSMITTER

 

PRESS RPROG

 

PUSHBUTTON 

LED TURNS OFF

 

NOTE: To program transmitters onto different channels, press and hold the red RADIO PROG pushbutton until the LED for 

that channel turns on, then release the RADIO PROG pushbutton and press the transmitter. 

Total Reset

 

OPEN TOP

 

END RESET

 

 

PRESS & HOLD RPROG

 

PUSHBUTTON 

BRIDGE MR 

SEVERAL BEEPS

 

  PRESS RPROG

 

PUSHBUTTON 

LED TRUNS OFF

 

Summary of Contents for ML8NF

Page 1: ...User s Manual ML8NF RSENS...

Page 2: ...ramming 8 Radio Manual Programming 8 Total Reset 8 Safety Safety Safety Safety devices devices devices devices programming programming programming programming 9 RadioSens3 Transmitter Programming in R...

Page 3: ...installation connecting it to the STOP terminal For correct use of the security edge this must never be activated when the door is fully closed It is wiseto install the ends of run before activating...

Page 4: ...eviceinstaller Examine the installation frequently especiallythecables springs and supports to detect signs of wear damage or unbalance Do not use the door if repair work or adjustments are required a...

Page 5: ...otor power 750W 1200W intensive use residential use Standby operating consumption 23mA 43mA Motor fuses 6A Optionalcards RSEC3 MEM 500 V XPAN TL CARD V Free voltage output 2 outputs 12Vdc output 1 fix...

Page 6: ...jcmtechnologies 6 Connection Motor connections U OPEN Brown V CLOSE Black W c COMMON Blue...

Page 7: ...Installation with support UNSCREW EXTRACT SUPPORT DRILL WALL HANG CONTROLPANEL SCREW Installation without support UNSCREW OPEN TOP DRILL WALL Door Positioning DOOR OPENED PRESS HOLDCLOSE AFTER FEW SE...

Page 8: ...PRESS RPROG PUSHBUTTON LED TURNS OFF NOTE To program transmitters onto different channels press and hold the red RADIO PROG pushbutton until the LED for that channel turns on then release the RADIO PR...

Page 9: ...f the system to the irregular conditions of the floor the equipment can be inhibited for the last 4cm at the end of the travel of the door In the inhibition zone obstacles will not be detected Setting...

Page 10: ...UTO DOOR STOPS AUTO AUTOCLOSE TIME PRESS START PUSHBUTTON DOOR CLOSES DOOR STOPS AUTO DOOR OPENS AUTO DOOR STOPSAUTO DOOR STOPS AUTO LED TURNS OFF END PROGRAMMING DOOR CLOSES AUTO INHIBITION ZONE INHI...

Page 11: ...EST INPUTS IN1 SEC CLOSE AUTOTEST NC IN2 START NO IN3 STOP NC RADIO INPUTS IN31 C1 START RADIO SEC_DM IN32 C2 DEAD MAN CLOSE IN33 C3 OPEN IN34 C4 CLOSE Regulatory Data EU Declaration of conformity J J...