jcm-tech ML8NF User Manual Download Page 10

jcm

technologies

 

10

 

Maneuver programming 

Programming the door maneuver with RadioSens3 system

 

DOOR CLOSED

 

 

PRESS  WHITE PROG

 

PUSHBUTTON 

LED TURNS ON

 

PRESS START 

PUSHBUTTON

 

DOOR OPENS 2 SECONDS 

DOOR CLOSES 

DOOR STOPS AUTO 

DOOR OPENS AUTO

 

DOOR STOPS AUTO 

AUTOCLOSE TIME

 

PRESS START

 

PUSHBUTTON 

DOOR CLOSES

 

DOOR STOPS AUTO 

DOOR OPENS AUTO 

DOOR STOPS AUTO

 

DOOR STOPS AUTO 

LED TURNS OFF 

END PROGRAMMING

 

DOOR CLOSES AUTO

 

*INHIBITION ZONE:

*INHIBITION ZONE:

Optionally  press    START    to  set 

inhibition point. From this point to 

the  closing  edge,  the  safety 

device  will  be  inhibited.  The 

inhibition zone  must  comply  with 

the  safety  standards,  it  must  be 

less than 40mm from the floor.

 

Summary of Contents for ML8NF

Page 1: ...User s Manual ML8NF RSENS...

Page 2: ...ramming 8 Radio Manual Programming 8 Total Reset 8 Safety Safety Safety Safety devices devices devices devices programming programming programming programming 9 RadioSens3 Transmitter Programming in R...

Page 3: ...installation connecting it to the STOP terminal For correct use of the security edge this must never be activated when the door is fully closed It is wiseto install the ends of run before activating...

Page 4: ...eviceinstaller Examine the installation frequently especiallythecables springs and supports to detect signs of wear damage or unbalance Do not use the door if repair work or adjustments are required a...

Page 5: ...otor power 750W 1200W intensive use residential use Standby operating consumption 23mA 43mA Motor fuses 6A Optionalcards RSEC3 MEM 500 V XPAN TL CARD V Free voltage output 2 outputs 12Vdc output 1 fix...

Page 6: ...jcmtechnologies 6 Connection Motor connections U OPEN Brown V CLOSE Black W c COMMON Blue...

Page 7: ...Installation with support UNSCREW EXTRACT SUPPORT DRILL WALL HANG CONTROLPANEL SCREW Installation without support UNSCREW OPEN TOP DRILL WALL Door Positioning DOOR OPENED PRESS HOLDCLOSE AFTER FEW SE...

Page 8: ...PRESS RPROG PUSHBUTTON LED TURNS OFF NOTE To program transmitters onto different channels press and hold the red RADIO PROG pushbutton until the LED for that channel turns on then release the RADIO PR...

Page 9: ...f the system to the irregular conditions of the floor the equipment can be inhibited for the last 4cm at the end of the travel of the door In the inhibition zone obstacles will not be detected Setting...

Page 10: ...UTO DOOR STOPS AUTO AUTOCLOSE TIME PRESS START PUSHBUTTON DOOR CLOSES DOOR STOPS AUTO DOOR OPENS AUTO DOOR STOPSAUTO DOOR STOPS AUTO LED TURNS OFF END PROGRAMMING DOOR CLOSES AUTO INHIBITION ZONE INHI...

Page 11: ...EST INPUTS IN1 SEC CLOSE AUTOTEST NC IN2 START NO IN3 STOP NC RADIO INPUTS IN31 C1 START RADIO SEC_DM IN32 C2 DEAD MAN CLOSE IN33 C3 OPEN IN34 C4 CLOSE Regulatory Data EU Declaration of conformity J J...