© 2020, JAPAN CASH MACHINE CO., LTD.
6 - 8
Section 6
UBA Pro RT/RQ™ Series Banknote Recycler
Calibration and Testing
DIP Switch Test
To perform the DIP Switch Test, proceed as fol-
lows:
1. Launch the Performance Test Program (see
2. Select “
RC_DIPSWTICH_TEST
” (Figure 6-34
a
).
3. Click the “
Start
”
Screen Button (Figure 6-
b
) to begin the Test.
4. Set the RT/RQ’s DIP Switch #1 through #8 to
ON
and
OFF
.
5. The resulting indication will appear in the “
RC-
Dip switch
a
) on the Screen.
6. Confirm that indication changes “
ON
” and
“
OFF
” as the Switch is set.
7. Click the “
Stop
”
Screen Button (Figure 6-
b
) to end the test.
RT Transport Performance Tests
This section provides instructions for conducting a
Performance Test Using a PC on the RT Transport
a
).
Feed Motor Speed Forward Rotation Test (RT
Transport)
To perform the Feed Motor Speed Test in the for-
ward rotation on the RT Transport side, proceed as
follows:
1. Ensure that the Recycler and Cash Box is prop-
erly installed.
2. Launch the Performance Test Program (see
page 6-7).
3. Select “
TWIN_FEED_MOTOR_FWD_TEST
”
a
).
4. Click the “
Start
”
Screen Button (Figure 6-
b
) to begin the Test.
5. The measured speed will appear in the “
RC-Feed
Motor (RC-Twin)
a
) on the
Screen.
6. Confirm that the motor speed is in the acceptable
range: 600mm/sec to 900mm/sec.
7. Click the “
Stop
”
Screen Button (Figure 6-
b
) to end the test.
Figure 6-34
Figure 6-34
DIP Switch Test 1
a
b
Figure 6-35
Figure 6-35
DIP Switch Test 2
DIP Switches #1 - #8 ON or OFF
ON
1
2
3
4
5
6
7
8
Figure 6-36
Figure 6-36
DIP Switch Test 3
a
b
Figure 6-37
Rotation Test (RT Transport) 1
Figure 6-37
Feed Motor Speed Forward Rotation
Test (RT Transport) 1
a
b
Figure 6-38
Figure 6-38
Feed Motor Speed Forward Rotation
Test (RT Transport) 2
a
b