background image

P/N 960-000167R_Rev. 1 {EDP #214645} 

© 2013, Japan CashMachine Co., Limited

1 2

DT-300™ Series Download Tool Operator Integration Guide

4.  Once the update is complete, the LCD Screen will 

display the “

Bootloader X.XX Succeeded.

” mes-

sage (See Figure 53).

Power Management

M

ONITORING

 B

ATTERY

 C

HARGE

 L

EVEL

Three (3) Levels of a Battery Charge condition 

exist: FULL, LOW and EMPTY. The DT-300™ 

Unit’s performance is limited by the Battery condi-

tion. Table 10 lists the DT-300™ available perfor-

mance for each Battery condition case. 

B

ATTERY

 C

ONDITION

 D

ISPLAY

The Battery condition is monitored regularly. When 

the Battery condition is EMPTY, the existing per-

formance Function will terminate, and all Func-

tions will no longer be available; the Error Display 

appears.

Table 11 lists the various Battery Condition Dis-

plays.

S

LEEP

 M

ODE

When no operation has been performed for 10 min-

utes, the DT-300™ Device will enter Sleep Mode 

automatically in order to extend its battery life

 

(See Figure 54)

. Once Power is re-supplied, or any 

Function Key is pressed, the DT-300™ will again 

be ready to begin operation. 

When the DT-300™ Device enters Sleep Mode 

while downloading the Software or receiving the 

Acceptance Log, the LCD Screen will display the 

following messages shown in Table 12. 

Table 10 

Performance and Battery Condition

Performance Function

Battery Condition

FULL

LOW

EMPTY

LCD Display

O

O

O

LCD Backlight

O

O

X

Key Input

O

O

X

Function Selection

O

O

X

Firmware Update Function

O

O

X

Statistics Function

O

O

X

Enabled Denomination Function

O

O

X

Error Message Function

O

O

X

Version Check Function

O

O

X

Maintenance Function

O

O

X

Acceptance Log Function

O

O

X

Language Function

O

O

X

Bootloader

*

*. When booting, check the Battery Charge Level. The Bootloader will be 

available only when the Battery is FULL. If the Battery condition is 

LOW or EMPTY, an error message will appear.

O

X

X

Figure 52 

EEPROM Update Progress Bar

Figure 53 

EEPROM Update Success Screen

Table 11 

Battery Condition Indication

Display

Condition

Battery FULL

Battery LOW

Battery EMPTY

Table 12 

Various Sleep Mode Screens 

Screen

Description

Download Complete

Download Failed

Acceptance Log 

Receipt Complete

Acceptance Log 

Receipt Failed

Figure 54 

Sleep Mode Screen

Summary of Contents for DT-300 Series

Page 1: ...Limited Support http www jcmglobal com en contact default aspx Web Site http www jcmglobal com Issue 4033 IGE 01 01 DT 300 Series Download Tool Operator Integration Guide Revision 1 April 1 2013 P N 9...

Page 2: ...ompanies Furthermore and are not always mentioned in each case throughout this publication International Compliance RoHS Directives CE Mark FCC Directives See below REVISION HISTORY Rev Date Reason fo...

Page 3: ...etting 6 Functions 6 Bootloader 6 MainApplication Normal Mode 6 Boot Mode 6 Authentication 6 USB Cable Connection 6 Operation Procedures MainApplication 6 Firmware Update Function 6 Statistics Functio...

Page 4: ...DT 300 Entire Unit Outside Dimensions 14 9 COMPATIBILITY 14 10 ERROR CODES 15 Bootloader Error Codes 15 MainApplication Error Codes 15 11 INTERNATIONAL COMPLIANCE 18 12 TECHNICAL CONTACT INFORMATION...

Page 5: ...en 7 Figure 15 Software Downloading Screen 7 Figure 16 Software Download Verifying Screen 7 Figure 17 Software Download Complete Screen 7 Figure 18 SD Card Confirmation Screen 2 7 Figure 19 Function S...

Page 6: ...42 Standby Screen 5 10 Figure 43 Acceptance Log Reading Screen 10 Figure 44 Log Read Complete Screen 10 Figure 45 SD Card Confirmation Screen 8 11 Figure 46 Function Selection Screen 8 11 Figure 47 L...

Page 7: ...ance Log 8 Table 7 Reading Denomination Table 8 Table 8 Log Storage Limit 10 Table 9 Acceptance Logs Available 10 Table 10 Performance and Battery Condition 12 Table 11 Battery Condition Indication 12...

Page 8: ...P N 960 000167R_Rev 1 EDP 214645 2013 Japan CashMachine Co Limited vi DT 300 Series Operator Integration Guide THIS PAGE INTENTIONALLY LEFT BLANK...

Page 9: ...ssignments Functions Unit Dimensions Compatibility Technical Contact Information In order to make operation of this device easier and make navigation within this manual simpler the following illustrat...

Page 10: ...features an LCD Display The Bootloader update and the MainApplication function selection are available by using the LCD Display The Acceptance Log Error Messages Version CRC Serial Number Maintenance...

Page 11: ...and repair should only be performed by a certified JCM Service Center or a professional technician Unauthorized repair use by inadequately trained personnel or use outside the manu facture s original...

Page 12: ...T LEFT Interface USB Host Single Channel USB 2 0 Full Speed SD Card SDHC acceptable USB is available for only JCM products access Display Monochrome LCD 122x32 dots with back light LED Light emitting...

Page 13: ...3 Save the Software Data Files xxxxxxxxx COM for each Model s Folder Refer to the Software Data File on page 13 of this Guide for more details SD CARD INSTALLATION INTO A DT 300 Perform the following...

Page 14: ...Validator to the DT 300 Device 1 Connect the USB Cable A Terminal to the DT 300 Unit s Connector A Port See Figure 9 a 2 Connect the USB Cable B or Mini B terminal to the Validator s USB Port See Fig...

Page 15: ...SB Cable See Figure 20 Once detected the connection between the Validator and the DT 300 will automatically begin to receive the Validator s Acceptance Log 4 The LCD Screen will display a Progress Bar...

Page 16: ...een shown in Figure 25 4 Press the OK Key to display the Denomina tion Table Screen See Figure 26 Press the CLR Key to return to the previous Function Selec tion Screen 5 Confirm that the current deno...

Page 17: ...election Screen and press the OK Key to select it See Figure 32 3 Ensure that the LCD displays the Standby Screen shown in Figure 33 4 Press the OK Key to display the Version CRC and Serial Number Ind...

Page 18: ...isplay a Progress Bar during the Acceptance Log reading process as shown in Figure 43 5 Once reading of the Acceptance Log is complete the LCD will display the Log Read Complete Screen shown in Figure...

Page 19: ...D Screen will display a Progress Bar during the Firmware updating pro cess as shown in Figure 49 4 Once the update is complete the LCD Screen will display the new Bootloader X XX Succeeded Message See...

Page 20: ...tion Key is pressed the DT 300 will again be ready to begin operation When the DT 300 Device enters Sleep Mode while downloading the Software or receiving the Acceptance Log the LCD Screen will displa...

Page 21: ...mmm_ssssssssssss_nnnn LOG mmm Model Name ssssssssssss Serial Number 12 digit decimal If the number was not read none nnnn Number 4 digit decimal e g UBA_0001 DAT iPRO1234 LOG NOTE The Backlight is li...

Page 22: ...OFF iVIZION System Type A Mini B VEGA Series Set DIP Switches 1 7 8 to ON and keep DIP Switches 2 through 6 OFF VEGA System Type A Mini B TBV 100 Series Set DIP Switches 1 6 7 8 to ON and keep DIP Swi...

Page 23: ...M Data File Access Error 11 E59 EEPROM Error EEPROM Data File Format Error 12 E60 EEPROM Error EEPROM Write Error 13 E61 SD Card Error Card Information File Authentication Error 14 E62 SD Card Error S...

Page 24: ...Error EEPROM Selected Language Write Error 39 E070 SD Card Error MMC Driver Initialize Error 40 E071 SD Card Error SD Card Power ON Error 41 E072 SD Card Error SD Card Power OFF Error 42 E073 SD Card...

Page 25: ...error 85 E420 Send Error Error Code Receive Request Error 86 E421 Receive Error Error Code Receive Response Error 87 E422 Mode Error SetMode 0x0A Command Send Error 88 E423 Mode Error SetMode 0xFF Com...

Page 26: ...mplies with Part 15 of FCC Rules Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference received including interfe...

Page 27: ...190 837 7834 Unit B Third Avenue Denbigh West Business Park Bletchley Milton Keynes Buckinghamshire MK1 1DH UK E mail support jcm uk com ASIA OCEANIA JCM GOLD HK LTD Phone 852 2429 7187 Fax 852 2929...

Page 28: ...P N 960 000167R_Rev 1 EDP 214645 2013 Japan CashMachine Co Limited 2 0 DT 300 Series Download Tool Operator Integration Guide THIS PAGE INTENTIONALLY LEFT BLANK...

Page 29: ...tion steps required for 5 N Navigation within manual procedure for 1 P Pin Assignments 51 Pin D Sub Connector Table Listing of 13 Precautionary Symbols types of 3 Primary Features DT 300 Product Serie...