Maintenance
Electrical System
77
9831/3200-3
77
Refer to: Access Apertures (Page 63).
3. If the machine has a battery isolator, then disconnect the battery isolator.
Refer to: Battery Isolator (Page 22).
4. Disconnect the battery leads. Disconnect the earth (-) terminal first.
Check (Electrolyte Level)
(For: Lead Acid Battery)
WARNING
Do not top the battery up with acid. The electrolyte could boil out and burn you.
1. Make the machine safe.
2. Open the battery compartment cover.
3. Remove the vent caps.
4. Check the electrolyte level.
4.1. The minimum level is at the top of the plates.
4.2. If necessary, add just enough distilled water to cover the plates at this time.
5. Install the vent caps.
6. Put batteries on a complete charge before adding any additional distilled water.
7. Remove the vent caps.
8. Add distilled water until the electrolyte level is below the bottom of the fill well by the specified value.
Distance: 3.175mm
8.1. If necessary, use a piece of rubber as a dipstick to determine this level.
Figure 48.
A
A
Electrolyte level (3.175mm)
9. Clean the vent caps.
10. Install the vent caps.
Check (Charge Level)
WARNING
Do not connect the charger when the batteries are not connected. Doing so could result in
danger of live terminals from the charger.
Do not carry out maintenance on a machine whilst the charger is connected to an external power supply
(i.e. do not work on a live machine). Cables from the charger to the batteries may remain live even if the
batteries are disconnected/removed from the machine. There is a risk of serious electrical shock.
Summary of Contents for S1530E
Page 2: ......
Page 4: ...9831 3200 3 Notes...
Page 16: ...About the Product Description 8 9831 3200 3 8 Y Charging plug Z Power to platform plug...
Page 29: ...Operation Entering and Leaving the Operator Station 21 9831 3200 3 21 Figure 12 A A Lever...
Page 35: ...Operation Slopes 27 9831 3200 3 27 Figure 16 B A A Front back slope B Side slope...
Page 52: ...Notes 44 9831 3200 3 44...
Page 54: ...Notes 46 9831 3200 3 46...
Page 75: ...Maintenance Safety Equipment 67 9831 3200 3 67 Figure 41 A A Tilt sensor...
Page 90: ...Notes 82 9831 3200 3 82...
Page 119: ...Technical Data Warranty Information 111 9831 3200 3 111 Figure 76 11000h 132 Month h...
Page 120: ...Notes 112 9831 3200 3 112...