Assembly
Discharge Hose
Always use a commercially available hose and hose connector with the hose clamp provided with the pump. The
suction hose must be reinforced with a non-collapsible wall or braided wire construction.
Do not use a hose smaller than the pump’s suction port size. Minimum hose size: 80mm (3 inches)
It is best to use a short, large-diameter hose, because this will reduce fluid friction and improve pump output. A
long or small-diameter hose will increase fluid friction and reduce pump output.
The Assembly of the Discharge Hose is the same as Suction Hose in the previous Step
>
Place the Hose Coupler then Sealing Washer into the Coupler Ring. This can then be threaded onto the
Outlet.
>
The Discharge Hose can now be placed over the Hose Coupler (ensure the Hose Clamp is already over the
Discharge Hose when connecting it to the Coupler Assembly)
>
Ensure the Coupler Assembly and Hose Clamp are tight.
Coupler Assembly
Hose Clamp
Discharge Hose